Table 24.
Step
Action
Procedure
1
Set barrel for Motor Type
From the Maintenance menu (Figure 31.), open the
Motor Setup menu, shown in Figure 30.
2
Select the barrel
Use the Up and Down arrows to highlight the desired
barrel
3
Select the proper motor
type
Press the + or - buttons at the bottom of the display to
set the motor type to 1 for 60 Hz or 2 for 50 Hz
4
Complete the procedure
Press the BACK button at the bottom of the display to
save the settings and return to the Setup menu.
Viper Installation, Service & Decommissioning Manual
© 2022, Marmon Foodservice Technologies Inc.
- 35 -
Publication Number: 620073146SER
Figure 31. Select Screen
Table 25.
Step
Action
Procedure
1
Select Motor Setup
Use the Up and Down arrows to highlight MOTOR
SETUP on the Maintenance menu.
2
Select the barrel
Use the Up and Down arrows to highlight the desired
barrel
3
Start calibration
Press the CAL button at the bottom of the Motor
Setup menu to start the calibration process.
The calibration cycle continues for five (5) minutes to
allow the gearbox to stabilize at temperature and
ensure correct calibration. At that time the motor
stops and it is calibrated.
4
Complete the procedure
Press the BACK button at the bottom of the display to
return to the Maintenance menu.
5
Verify
Select SPIN to run the motor and visually ensure that
the calibration reading is 20 +/- 2.
Содержание R-454C
Страница 111: ...Cornelius Inc www cornelius com...