Use and Maintenance Manual – 09/2016 Rel. 0
Page 34
20.1 Error Codes
The machine indicates error conditions by alternating the display of the error code with a brief description (in English) pf the cause
of the error.
The list of error codes and brief descriptions are reported in table T20.1. The machine displays the code for different times depending
on the code of said error, as indicated in the “Error displayed” column in table T20.1.
Table T20.1: Error codes
Error
code
Brief description
Error
displayed
(1)
Description
Notes
000 a 009
INT ERR
Machine parameters internal error.
Contact technical support.
010
REV SPN
Reverse rotation of the wheel.
Contact technical support.
012
NO STP
The wheel cannot be stopped at the
end of the launch.
Check the mains voltage. If the checks do not
lead to any results, contact technical support.
014
NO SPN
The wheel does not spin.
Contact technical support.
015
(Codice del tasto
incastrato)
PERMANENT
UNTIL TURNED
OFF
Keypad blocked at start-up.
Release all buttons, then turn off or restart the
machine. If the error persists, contact technical
support.
018
NO BTI
Cannot communicate with the
expansion board.
Turn the machine off and the on again. If the
error persists, contact the technical support.
019
NO CP
OPERATOR
CONFIRMATION
Communication processor failure.
Turn the machine off and then on again. If the
error persists, contact technical support.
The machine can still be used but all functions
related to the USB port are disabled.
020
NO EEP
OPERATOR
CONFIRMATION
Lack of communication with the
eeprom memory.
Turn the machine off and then on again. If the
error persists, contact technical support.
021
EEP ERR
OPERATOR
CONFIRMATION
Lack of machine calibration data or
incorrect calibration data.
Carry out calibration for the CAR/SUV Wheel
Type and/or for the MOTO Wheel Type. If the
error persists, contact technical support.
See also ERR 030 and ERR031.
022 a 024
OPERATOR
CONFIRMATION
Error during calibration.
Excessive imbalance or anomaly. Turn the
machine off and then on again. If the error
persists, contact technical support.
026
NO –A-
OPERATOR
CONFIRMATION
A launch without weight or failure of
the pick-up A signal in the Cal2
calibration phase.
Apply the intended weight and repeat the
launch. If the error persists, contact technical
support.
027
NO –B-
OPERATOR
CONFIRMATION
A launch without weight or failure of
the pick-up B signal in the Cal2
calibration phase.
Apply the intended weight and repeat the
launch. If the error persists, contact technical
support.
028
INN IMB
OPERATOR
CONFIRMATION
Launch with weight on the internal
side during the Cal3 calibration phase.
In this phase, the weight must be on
the external side.
Remove the weight from the internal side and
repeat the launch. If the error persists, contact
technical support.
030
CAR CAL
OPERATOR
CONFIRMATION
Lack of calibration data for the
CAR/SUV Wheel Type.
Carry out calibration for the CAR/SUV Wheel
Type.
031
TRC CAL
OPERATOR
CONFIRMATION
Lack of calibration data for the TRUCK
(motorbike) Wheel Type.
Carry out machine calibration for the TRUCK
Wheel Type.
051
TOO FAR
OPERATOR
CONFIRMATION
Hidden Weights program: the
selected point is too far from the
external imbalance position.
The point must be included up to 120° from the
external imbalance position. See chapter 16.
052
NOT INC
OPERATOR
CONFIRMATION
Hidden Weights program: the
external imbalance position is not
between the selected W1 and W2
points.
Choose W1 and W2 points so that they include
the external imbalance position. See chapter
16.
054
Cannot communicate with the motor
inverter.
Turn the machine off and the on again. If the
error persists, contact the technical support.
055
NO OPT
OPERATOR
CONFIRMATION
The static imbalance of the wheel is
too low: the Optimization program
cannot be used.
Turn the machine off and the on again. If the
error persists, contact the technical support.
056
HIG TMP
Motor inverter overtemperature.
Turn the machine off, wait at least 10 minutes
and then turn the machine on again. If the error
persists, contact the technical support.
057
OVR VOL
Motor inverter overvoltage.
Turn the machine off and the on again. If the
error persists, contact the technical support.
058
UND VOL
Motor inverter undervoltage.
Turn the machine off and the on again. If the
error persists, contact the technical support.
059
SOV RA
Motor inverter overload.
Turn the machine off and the on again. If the
error persists, contact the technical support.
Содержание MEC 200 TRUCK
Страница 1: ...WHEEL BALANCERS MEC 200 TRUCK MEC 200 C TRUCK USE AND MAINTENANCE MANUAL UK...
Страница 2: ......
Страница 4: ......
Страница 43: ......