Use and Maintenance Manual – 09/2016 Rel. 0
Page 18
10
Press [P8] key Start
. The machine will run a launch.
11
At the end of the spinning, the inverter brake stops the wheels
in the position where showing the value of 300 on the left
display. Remove the 300 gr weight fixed on the internal side
and fix it on the external side of the wheel, at 12H.
12
Press [P8] key Start
. The machine will run a launch.
13
Calibration is finished: the machine automatically exits the
calibration program and returns to NORMAL mode, ready to
perform balancing.
14.3 Machine calibration for the CAR/SUV Wheel Type
The calibration for the CAR wheel type and SUV wheel type is the same.
To perform machine calibration, you must first provide for the following material:
•
A balanced wheel with steel rim that has the following dimensions: Diameter 15” Width 6”. The distance of the wheel from
the machine should be approximately 100 mm. It is also possible to use wheels with dimensions similar to those
recommended as long as the difference is minor. It is not possible to use wheels with aluminum rims;
•
A 50 grams weight (preferably in Iron or Zinc).
To perform the machine calibration, proceed as follows:
Phase
Description
1
Switch on the machine.
2
Press the [F+P3] button
. The display
will show the message in the picture on the left (this indicates
that we have entered Service mode).
3
Press the [P3] button
. The message in the picture on
the left will be shown on the display (machine calibration for
TRUCK wheels).
4
Press the [P4] button
to select the machine
calibration for CAR/SUV wheels.
5
Remove the wheel and any other accessories from the shaft.
6
Press the [P3] button
. The display will show the
message in the picture on the left.
7
Press [P8] key Start
. The machine will run a launch.
At the end the display will show the message in the picture on
the left.