Use and Maintenance Manual – 09/2016 Rel. 0
Page 9
Figure F6.22 and Figure F6.23: Remove the wheel guard from the packaging and place it on the tube.
Figure F6.24: Secure the wheel guard to the red tube using the relative ties.
6.4 Electrical connection
The standard version of the machine must be connected to a mains 230V SINGLE PHASE.
The change of the power supply cannot be realized by the user; it must be requested to CORMACH s.r.l. or to a dealer or to an
authorized service center. To accomplish the electric connection, connect the machine’s power supply cable with the plug in use in
the country.
ALL OPERATIONS TO MAKE ELECTRICAL CONNECTION AND INTERVENTIONS (HOWEVER LIGHT) ON
ELECTRICAL PARTS MUST BE CARRIED OUT BY QUALIFIED PERSONNEL.
The dimensioning of electrical connection must be carried out in according to electric power absorbed by the machine. The
absorption is specified in paragraph 10. The user must:
- check that the supply voltage correspond to the voltage indicate on the nameplate of the machine;
- check the conditions of the wire and the presence of the ground conductor;
- check the machine is connected to its own electrical connection, fitted with a proper 30 mA sensitive automatic circuit breaker,
against a possible electrical overload over 30 mA;
- connect the power supply cable to the plug with great care and following to the current regulations.
WHEN THE MACHINE IS TURNED OFF FOR A LONG TIME IT IS NECESSARY TO DISCONNECT THE POWER PLUG
TO AVOID USE BY UNAUTHORIZED PERSONNEL.
IF THE MACHINE IS CONNECTED DIRECTLY TO THE POWER SUPPLY BY MEANS OF THE MAIN ELECTRICAL
BOARD AND WITHOUT THE USE OF A PLUG, INSTALL A KEY-OPERATED SWITCH TO RESCTRICT THE MACHINE
USE EXCLUSIVELY TO QUALIFIED PERSONNEL.