8.

 

Press the [P3] key  

 to change the diameter and press the [P4]  

 or [P5]   

  within 1.5 seconds to 

enter the read value. If neither of these two buttons is pressed in this time limit, the machine will return to the previous 

display. In this case, you can press the [P3] key again  

 to enter or edit the data. 

Figure F15.2: Manual acquisition of the wheel size: distance sensor fixing 

 

 
15.3.2 Entering wheel size for Program Types ALS1, ALS2 
To manually enter a wheel size, proceed as follows: 

1.

 

Fit the wheel on the shaft; 

2.

 

If the selected program type is ALS1, extract the distance sensor and place it on the wheel as shown in Figure F15.3 
otherwise proceed with step 4; 

3.

 

If the selected program type is ALS2, remove the distance sensor and place it on the wheel as shown in Figure F15.4; 

4.

 

Read the internal plane distance value on the graduated scale. The distance value is always expressed in millimetres; 

5.

 

Press the [P1] key once  

  to view the parameter 

di1

 

(

internal plane distance) and, within 1.5 seconds, press the 

[P4]  

 or [P5] key  

 to enter the read value. If neither of these two buttons is pressed in this time limit, 

the machine will return to the previous display. In this case, you can press the [P1] key again  

  to enter or edit the 

data; 

6.

 

Remove the distance sensor and place it on the plane selected for the external weight as shown in Figure F15.5; 

7.

 

Read the distance value on the graduated scale. The distance value is always expressed in millimetres; 

8.

 

Press the [P1] key  

  twice in quick succession until 

di2

 

(

external plane distance) is viewed and, within about 1.5 

seconds, press [P4]  

  or [P5]  

  to enter the read value. If neither of these two buttons is pressed in this 

time limit, the machine will return to the previous display. In this case, you can press [P1] key 

 

  

twice in rapid 

sequence to enter or edit the data; 

9.

 

Press [P3] key  

  to view 

da1

 

(

internal plane diameter) and within about 1.5 seconds press [P4]  

  or [P5]  

  to enter the value obtained with one of the two methods specified in the below note. If neither of these two 

Содержание MEC 200 TRUCK

Страница 1: ...WHEEL BALANCERS MEC 200 TRUCK MEC 200 C TRUCK USE AND MAINTENANCE MANUAL UK...

Страница 2: ......

Страница 3: ...08 EC Electromagnetic Compatibility Directive EMC The following harmonized standards have been applied EN 60204 1 2006 A1 2009 EN ISO 11202 2010 EN ISO 12100 2010 EN ISO 13850 2012 EN ISO 13857 2008 T...

Страница 4: ......

Страница 5: ...erraille de la machine et de ses composants doit tre effectu e la conformit aux Directive suivante Verschrottung mu gem der folgenden Vorschrift durchgef hrt werden 2012 19 EU RAEE E le disposizioni d...

Страница 6: ...bject to sanctions according to the national Laws of the Country of destination Abandonment or wrong scrapping of the equipment subject to Directive 2012 19 EU can cause serious damage to the environm...

Страница 7: ...Type Page 18 15 Use of the machine in normal mode Page 20 15 1 Program Type selection Program Type Page 20 15 2 Wheel Type selection Wheel Type Page 21 15 2 1 CAR wheel type Page 21 15 2 2 TRUCK wheel...

Страница 8: ...manual before using the machine The manufacturer is not responsible for damages and injury caused by failure to follow the instructions of this manual We also recommend Keep the manual near wheel bala...

Страница 9: ...Y UNAUTHORIZED PERSONNEL OR FROM USE IMPROPER INCORRECT AND UNREASONABLE OF THE WHEEL BALANCER THE WHEEL BALANCER SHOULD NOT BE MODIFIED OR TAMPERED WITHOUT PERMISSION OF MANUFACTURER ANY UNAUTHORIZED...

Страница 10: ...e are no damaged parts In case of doubt DO NOT USE THE MACHINE and consult qualified personnel dealer or manufacturer The packaging materials plastic bags nails screws pieces of wood etc must not be l...

Страница 11: ...in Figure F6 2 and screw no 4 M6 screws Figure F6 3 Figure F6 2 Figure F6 3 030 Prepare the sheet metal front support by running the cables as shown in figure F6 4 Figure F6 4 040 Fit the sheet metal...

Страница 12: ...ith its CPU board to the sheet metal front support Figure F6 9 Figure F6 9 070 Secure the head with no 4 M6 screws Figure F6 10 6 2 Installing lift 010 Fit the filter regulator in the wheel balancer r...

Страница 13: ...or the lift control fig 6 13 Slide the lift and make it lift by the relevant control Figure F6 13 Figure F6 14 030 Fix the ramp support to the lift with the relevant screws Figure F6 15 040 Fix the li...

Страница 14: ...the wheel spinning up and down Figure F6 19 6 3 Installing wheel guard and wheel guard support if present The wheel protection cover and its support is an ACCESSORY If delivered it must be mounted ac...

Страница 15: ...electrical connection must be carried out in according to electric power absorbed by the machine The absorption is specified in paragraph 10 The user must check that the supply voltage correspond to...

Страница 16: ...ven in Figure F7 1 Figure F7 1 From working position the user must be able to view the machine and the surrounding area INSTALLATION AREA MUST BE KEEP CLEAR BY POSSIBLE DANGEROUS OBJECTS UNAUTHORIZED...

Страница 17: ...en you purchase this product your supplier will also inform you that you may return another worn out appliance to him free of charge provided it is of the same type and has provided the same functions...

Страница 18: ...ic stop on the imbalance positions Automatic search for imbalance positions SWI Stop the Wheel on Imbalance Distance sensor designed for sticking adhesive weights CFC Car wheels calibration with zero...

Страница 19: ...routine maintenance CLEANING AND ORDINARY MAINTENANCE MUST BE PERFORMED BY THE AUTHORIZED PERSONNEL IN ACCORDANCE WITH THE MANUFACTURER INSTRUCTIONS PROVIDED BELOW Always keep the flanges clean and ti...

Страница 20: ...ne del Tipo di Ruota selezionato 2 Unit of measure light indicator inches red led on mm red led off 3 8 Display shows unbalance value inside outside 4 9 Light indicators show angular unbalance positio...

Страница 21: ...y function of the keys press the key P7 then by holding down press one of the keys for the secondary function you want then release both keys Figure F13 3 Numbering of the secondary function of the ke...

Страница 22: ...In these cases simultaneously the spin will start 14 MACHINE CALIBRATION To operate properly the machine must be calibrated Calibration allows storing the mechanical and electrical parameters specifi...

Страница 23: ...ssage in the picture on the left will be shown on the display machine calibration for TRUCK wheels 4 Remove the wheel and any other accessories from the shaft 5 Press the P3 button The display will sh...

Страница 24: ...meter 15 Width 6 The distance of the wheel from the machine should be approximately 100 mm It is also possible to use wheels with dimensions similar to those recommended as long as the difference is m...

Страница 25: ...weight 13 Press P8 key Start The machine will run a launch 14 Calibration is finished the machine automatically exits the calibration program and returns to NORMAL mode ready to perform balancing If t...

Страница 26: ...Normally the weights should be applied at the 12 o clock with the exception of special programs for ALS1 and ALS2 aluminum 15 1 Type of program Program Type The machine allows the choice between eight...

Страница 27: ...of the weight is at 6 o clock 15 2 Wheel types The machine allows choosing between three different Wheel Types as listed in table T15 3 Table T15 3 Wheel Types to select Wheel Type Vehicle Notes CAR A...

Страница 28: ...s The dimensions of the wheel to balance can be entered in manual mode only Note All machines are equipped with a graduated scale for manually measuring distance 15 3 1 Entering wheel dimensions for P...

Страница 29: ...d in millimetres 5 Press the P1 key once to view the parameter di1 internal plane distance and within 1 5 seconds press the P4 or P5 key to enter the read value If neither of these two buttons is pres...

Страница 30: ...alues to be entered are shown in table T15 4 Table T15 4 Measurement of diameters da1 and da2 to manually enter data Program Type Internal diameter da1 External diameter da2 ALS1 Enter the nominal rim...

Страница 31: ...o the rim internal edge 16 HIDDEN WEIGHTS PROGRAM This program divides the external weight W into two weights W1 and W2 smaller than the initial external weight W located in either of two positions se...

Страница 32: ...o continue with the next step Figura F16 3 Input della posizione del peso W2 8 Clockwise manually spin the wheel passing the unbalance point found before up to select the second spoke at 6H behind whi...

Страница 33: ...memory of operator 1 is stored 2 Perform all desired settings for wheel dimensions Program Type Wheel Type and unit of measurement The settings of operator 1 are stored in memory 3 Perform balancing...

Страница 34: ...chine will display the message visible in figure F18 1 for one second and the LED next to the button lights up Imbalance values are now displayed in X1 resolution high resolution Figure F18 1 Enabling...

Страница 35: ...run the SWI procedure Notes Automatic At the end of every launch Machine This is performed only if there is at least one imbalance value on the wheel Otherwise conventional braking will occur Low spe...

Страница 36: ...er messages See figure F19 1 Figure F19 1 SERVICE mode enabled 3 To exit the SERVICE mode you must first exit any Menus and test programs and return to the messages display shown in figure F19 1 4 Pre...

Страница 37: ...technical support personnel and is not described in this manual P9 Not used This button is not currently used in SERVICE mode F P1 Not used This button is not currently used in SERVICE mode F P3 Exit...

Страница 38: ...mber of shaft RPMs test This test allows you to control the number of shaft RPMs during the launch A number indicating the speed of the shaft will be viewed on the right display By pressing P8 key Sta...

Страница 39: ...otherwise the value measured will be completely meaningless 2 Press P8 key Start or lower the guard when present the machine will perform a sequence of brief motor ignitions each time letting the sha...

Страница 40: ...hout weight or failure of the pick up A signal in the Cal2 calibration phase Apply the intended weight and repeat the launch If the error persists contact technical support 027 NO B OPERATOR CONFIRMAT...

Страница 41: ...g one or more values in the permanent memory eeprom of the circuit board One or more values have been stored in the permanent memory of the circuit board for example at completion of calibration phase...

Страница 42: ...ment Hydraulic YES NO NO Foam YES YES NO Powder YES YES YES CO2 YES YES YES YES Can be used in the absence of more appropriate means or for small fires The information in the table above is general an...

Страница 43: ......

Страница 44: ...CORMACH S r l via A Pignedoli 2 42015 CORREGGIO RE ITALY Tel 39 0522 631274 Fax 39 0522 631284 e mail cormach cormachsrl com www cormachsrl com...

Отзывы:

Похожие инструкции для MEC 200 TRUCK