www.cooperbussmann.com/wirelessresources
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual
95
Rev Version 1.1
CLI Commands
Level Description
Example
system description
[System Description]
G
Set switch system description string.
switch>enable
switch#configure
switch(config)#system description xxx
system contact
[System Contact]
G
Set switch system contact window
string.
switch>enable
switch#configure
switch(config)#system contact xxx
show system-info
E
Show system information.
switch>show system-info
System Event Log Command
CLI Commands
Level Description
Example
show syslog
P
Show SYSLOG configuration and log
table.
switch>enable
switch#show syslog
System Reboot Command
CLI Commands
Level Description
Example
reload
G
Reboot switch.
switch>enable
switch#configure
switch(config)#reload
System Warning Commands
CLI Commands
Level Description
Example
syslog mode
[client|server|both]
G
Specified the log mode.
switch>enable
switch#configure
switch(config)# syslog mode both
syslog ip
[IP address]
G
Set system log server IP address.
switch>enable
switch#configure
switch(config)# syslog ip
192.168.1.100
show syslog
P
Show SYSLOG configuration and log
table.
switch>enable
switch#configure
switch#show syslog
no syslog
G
Disable system log functon.
switch>enable
switch#configure
switch(config)#no syslog
event system-restart
syslog
G
Set device restart event type.
switch>enable
switch#configure
switch(config)#event system-restart
syslog
event authentication-
failure syslog
G
Set Authentication failure event type.
switch>enable
switch#configure
switch(config)#event authentication-
failure syslog
event syslog
[Link-UP|Link-Down|Both]
I
Set port event for SYSLOG.
switch>enable
switch#configure
switch(config)#interface fastethernet 3
switch(config-if)#event syslog both