Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual
Rev Version 1.1
Add
Adds the new access profile.
Remove
Removes the access profile selected in the Current Access Tables list.
Use the MIB View tab to configure the management information base (MIB) table.
Figure 36 SNMPv3 MIB View Tab
Current MIB Tables
Lists the existing MIB views.
View Name
Enter the name of the MIB view to be added (or removed).
Sub-OID Tree
Enter the OID defining the root of the subtree to which the view will be included or
excluded.
Type
Select whether the sub-OID tree should be included with or excluded from the named
view.
Add
Adds the new MIB view.
Remove
Removes the MIB view selected in the Current MIB Tables list.
6.4.7 System Alert
System Alert Relay Alarm
The Fault Relay Alarm function provides power failure and port link down/broken detection. To configure this
function, choose
System
-->
System Alert
-->
Relay Alarm
.
For the power failure settings, if the power input 1 and power input 2 are installed and the checkboxes for PWR 1
and PWR 2 are selected the fault LED on the front panel will turn on when a power failure occurs.
For the Port Link Down/Broken setting, if the checkbox for a port is selected the fault LED will turn on when that
port fails. See “3.5 Wiring the Fault Alarm Contact” for information on failure detection.