Figure 37 System Alert - Relay Alarm (Fault Relay Alarm)
Power Failure
Setting
Select the checkbox if you want the fault LED indicator on the panel to turn on when
power fails.
Port Link Down/
Broken Setting
Select the port checkbox if you want the fault LED on the panel to turn on when the
port link is down or broken.
Apply
Click to apply the setting.
System Alert Event
If the Syslog Mode is enabled on the Syslog Configuration page (see “6.4.5 Syslog”) you can use the System Alert-
Event page to select which whether system restart, power status, and SNMP authentication failure events are sent
to the Syslog server.
To display this page, choose
System
-->
System Alert
-->
Event
.
NOTE If you also want the port event log to be sent to the Syslog server, be sure to set the triggers (link
up, link down, and both) in the Port Alert page (see “Port Alert”).
Figure 38 System Alert - Event