Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual

Rev Version 1.1

Kernel Version

Kernel software version.

Device MAC

Unique hardware address assigned by the manufacturer.

System Time

Current time on switch.

Enable Location Alert

Click to cause the fault LED on the switch to flash.

Asset

The Asset page allows you to change switch settings, including the system name, description, location, and contact 
information. Choose 

System

-->

General

-->

Asset

 to display this page.

Figure 23  Asset Page

System Name

Assign the system name of the switch (the maximum length is 64 bytes).

System Description

Switch description.

System Location

Physical location of the switch (the maximum length is 64 bytes).

System Contact

Name of contact person or organization.

System OID:

SNMP OID of switch.

Firmware Version

Displays the switch’s firmware version.

Kernel Version

Displays the kernel software version.

Device MAC

Displays the unique hardware address assigned by manufacturer.

Apply

Click to apply the settings.

CPU Load Average

To display the CPU load average for the switch, choose 

System

-->

General

-->

CPU Load Average

. The load 

is averaged over the previous 1-minute, 5-minute, and 15-minute intervals, as shown in Figure 24. The X-axis 
indicates the minute intervals, and the Y-axis indicates the average CPU load. When the average CPU load reaches 
90% the system logs an Event Alarm to the Syslog if the 

Syslog

 checkbox is selected under Event Alarm Setting at 

the bottom of the page. To enable the Syslog, see “6.4.5 Syslog.” 

Содержание 5073E-T

Страница 1: ...Read and Retain for Future Reference Cooper Bussmann 5073E T Managed Ethernet Switch User Manual Version 1 1 ...

Страница 2: ... to be non hazardous before servicing or replacing the unit and before installing the unit FCC Warning This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate ...

Страница 3: ...ch applies to firmware version 1 11 Follow Instructions Read this entire manual and all other publications pertaining to the work to be performed before installing operating or servicing this equipment Practice all plant and safety instructions and precautions Failure to follow the instructions can cause personal injury and or property damage Proper Use Any unauthorized modifications to or use of ...

Страница 4: ...ation 31 Syslog Log 32 6 4 6 SNMP 32 SNMP Agent 32 SNMP Trap Configuration 33 SNMPv3 34 6 4 7 System Alert 38 System Alert Relay Alarm 38 System Alert Event 39 Digital Input Digital Output 40 6 4 8 DHCP Server 42 DHCP Server Configuration 42 DHCP Server Client Table 43 DHCP Server IP Binding 43 6 5 Configure Menu 44 6 5 1 Port 44 Port Configuration 44 Port Status 45 Port Statistics 45 Port Alert 4...

Страница 5: ...fault Command 83 Fault Alarm Commands 83 IGMP Commands 84 IP Security Commands 85 IP Setting Commands 85 LLDP Commands 86 Loading Average Commands 86 Logout Command 86 MAC Address Table Commands 86 MAC Blacklist Commands 87 Multicast Static Filtering Table Commands 87 Ping Command 88 Port Control Commands 88 Port Monitoring Commands 89 Port Security Commands 89 Port Statistics Commands 90 Port Sta...

Страница 6: ...ments demanded by industrial applications The switch s fiber port can extend the connection distance increasing network elasticity and performance 1 1 Module Identification The identification label is on the bottom of the 5073E T Switch This label contains the model number temperature range power range serial number and all certifications Figure 1 Module Identification Label 1 2 Mechanical Specifi...

Страница 7: ... Port 1 488 000 pps for Gigabit Fiber Ethernet Port Packet Buffer 1 Mbits MAC Address 8K MAC Address Table Flash ROM 4 Mbytes DRAM 32 Mbytes Connector 10 100TX 7 x RJ 45 10 100 1000T Mini GBIC Combo 3 x RJ 45 3 x 100 1000 SFP Sockets RS 232 Connector RJ 45 type Network Cable 10Base T 2 pair UTP STP Cat 3 4 5 5E cable EIA TIA 568 100 ohm 100 m 100Base TX 2 pair UTP STP Cat 5 5E cable EIA TIA 568 10...

Страница 8: ...C 1215 Trap RFC1213 MIBII RFC 1157 SNMP MIB RFC 1493 Bridge MIB RFC 2674 VLAN MIB RFC 1643 Ethernet like RFC 1757 RMON RSTP MIB Private MIB el5073et mib LLDP MIB VLAN Port Based VLAN IEEE 802 1Q Tag VLAN 256 entries VLAN ID up to 4K VLAN ID can be assigned from 1 to 4094 GVRP 256 Groups Port Trunk with LACP LACP Port Trunk five Trunk groups Maximum four Trunk Members LLDP Supports LLDP allowing sw...

Страница 9: ...1A 24 Vdc SNMP Trap Link up trap Link down trap Cold start trap Authentication failure Private Specific Trap DC power status trap Digital input trigger configurable Topology change trap DHCP Provides DHCP client DHCP server port and IP binding DNS Provides DNS client feature and supports primary and secondary DNS server SNTP Supports SNTP to synchronize system clock in Internet Firmware Update Sup...

Страница 10: ... front panel includes seven 10 100 TX RJ 45 ports three 10 100 1000T Mini GBIC Combo ports each with an RJ 45 and a 100 1000 SFP connector one RS 232 connector RJ 45 type for connecting to a console terminal or PC and diagnostic LEDs Console Port Terminal Blocks 10 100 TX Ports 7 Dual Speed Mini GBIC Combo Ports 2 LEDs 10 100 1000 RJ 45 Connectors 100 1000 SFP Connectors 10 100 1000 RJ 45 Connecto...

Страница 11: ...dicators The diagnostic LEDs are located on the front panel of the industrial switch and provide real time information about the system The following table describes each LED state LED Color State Description Pwr Green On The switch unit is powered on Off No power R Master Green On The switch is a master in Pro Ring2se group Off The switch is a slave in Pro Ring2se group or Pro Ring2se is disabled...

Страница 12: ...s attached Green Lower LED On 1000 M Off 10 100 M Link Active P7 P9 P10 SFP Green On The SFP port is linking Blinking The port is transmitting or receiving packets from the TX device Off No device is attached P1 P6 P8 Green On A network device is detected Blinking The port is transmitting or receiving packets from the TX device Off No device attached Amber On The port is operating in full duplex m...

Страница 13: ... cable for the Ethernet connection 5 Insert one end of the RJ 45 Category 5 cable into the Ethernet port RJ 45 port on the 5073E T Switch and insert the other end of the same cable into the Ethernet port RJ 45 port on the network device a switch PC or server The UTP port RJ 45 LED on the 5073E T will turn on when the cable is connected to the network device See 2 3 LED Indicators for details about...

Страница 14: ...dustrial switch from the track reverse the steps above 3 3 Wall Mount Plate Mounting Follow these steps to mount the switch using a wall mount plate 1 Loosen the screws to remove the DIN rail from the 5073E T Switch 2 Place the wall mount plate on the rear panel of the switch 3 Use the screws to screw the wall mount plate onto the switch 4 Use the hook holes at the corners of the wall mount plate ...

Страница 15: ... Power Inputs Use the following steps below to insert the power wire 1 Insert the DC power wires into the contacts for power 1 and power 2 as shown below Power 2 Power 1 2 Tighten the wire clamp screws to prevent the wires from coming loose Power 2 Power 1 NOTE The wire gauge for the terminal block should be within the range 12 24 AWG ...

Страница 16: ...e fiber cable You can connect two devices up to 32 km apart The fiber segment using the multi mode connector type must use 50 or 62 5 125 µm multi mode fiber cable You can connect two devices up to 2 km apart Gigabit Copper SFP Mini GBIC Combo Port The 5073E T Switch has three auto detected gigabit cooper SFP ports which are the Mini GBIC Combo ports These ports should use Category 5e or above UTP...

Страница 17: ...ceiver into the SFP port even without a fiber connection to the remote the connection of the accompanying copper port will link down immediately Follow these steps to connect the transceiver and LC cable 1 Insert the SFP transceiver module into the SFP Mini GBIC port Notice that the triangle mark is on the bottom of the module Figure 8 Transceiver to SFP Module Figure 9 Transceiver Inserted 2 Inse...

Страница 18: ...per Bussmann 5073E T Managed Ethernet Switch User Manual Rev Version 1 1 Figure 11 Remove LC Connector b Pull out the plastic handle to release the transceiver and then grasp the tranceiver and pull it out Figure 12 Pull Transceiver Out of SFP Port ...

Страница 19: ... 13 Sample Application 4 1 Pro Ring2se Application Pro Ring2se is a new ring mechanism for the Cooper Bussmann ELPRO Technologies Industrial Ethernet Switches As Figure 15 shows Pro Ring2se can be constructed using two ports of the same type in each 5073E T Refer to 6 5 5 Redundancy Pro Ring2se for information on configuring each switch to enable the Pro Ring2se feature NOTE Pro Ring2se is not com...

Страница 20: ...20 www cooperbussmann com wirelessresources Cooper Bussmann 5073E T Managed Ethernet Switch User Manual Rev Version 1 1 Figure 15 Pro Ring2se Connection Examples ...

Страница 21: ...r to Appendix B COMMAND SETS for command descriptions and examples 5 1 Connecting to the Console Port A RS 232 to RJ 45 connector cable is supplied with the switch Figure 16 Connect the RS 232 connector to PC or terminal and the RJ 45 connector to the console port of the 5073E T switch The connected terminal or PC must support a terminal emulation program such as HyperTerminal or PuTTY Figure 16 R...

Страница 22: ... and configure its communication parameters to match the following default characteristics of the console port Baud Rate 9600 bps Data Bits 8 Parity None Stop Bit 1 Flow control None Figure 18 Communication Parameters 3 After setting the communication parameters click OK 4 At the blank screen press Enter to display the login prompt 5 At the login prompt Figure 19 type the default user name admin a...

Страница 23: ... Version 1 1 5 4 CLI Management The system supports the console management CLI commands After logging on to the system you will see a command prompt To enter the CLI management interface type the enable command See Appendix B COMMAND SETS for command descriptions and examples Figure 20 CLI Command Interface ...

Страница 24: ...he 5073E T Web based management utility 6 1 Preparing for Web Management Before using the Web based Management Utility install the 5073E T Switch on the network and make sure that all PCs on the network can connect with the switch through the Web browser The default IP address subnet mask username and password for the 5073E T Switch are as follows IP Address 192 168 1 88 Subnet Mask 255 255 255 0 ...

Страница 25: ... Figure 21 Home Page Web based Management Utility 6 4 System Menu 6 4 1 General Switch Information The Switch Information page Figure 22 appears when you log on to the Web based Management utility You can also display this page by choosing System General Switch Information Switch information includes the system name description location and contact personnel to identify the switch The information ...

Страница 26: ...n Physical location of the switch the maximum length is 64 bytes System Contact Name of contact person or organization System OID SNMP OID of switch Firmware Version Displays the switch s firmware version Kernel Version Displays the kernel software version Device MAC Displays the unique hardware address assigned by manufacturer Apply Click to apply the settings CPU Load Average To display the CPU ...

Страница 27: ...lified version of NTP which is an Internet protocol used to synchronize the clocks of computers to a specified time reference Because time typically advances the time on various node stations will be different For the communicating programs running on those devices this causes time to jump forward and backward an undesirable effect Therefore the switch provides comprehensive mechanisms to access n...

Страница 28: ...nes SNTP Sever Address Sets the SNTP server IP address You can enter the IP address of a local network time server or an Internet time server Daylight Saving Time Allows you to enable or disable the Daylight Saving Period and Daylight Saving Offset settings When enabled the Daylight Savings settings are in effect and when disabled these settings are ignored Daylight Saving Period Sets the daylight...

Страница 29: ...Hawaiian Standard 10 hours 2 am Nome Alaska 11 hours 1 am CET Central European FWT French Winter MET Middle European MEWT Middle European Winter SWT Swedish Winter 1 hour 1 pm EET Eastern European USSR Zone 1 2 hours 2 pm BT Baghdad USSR Zone 2 3 hours 3 pm ZP4 USSR Zone 3 4 hours 4 pm ZP5 USSR Zone 4 5 hours 5 pm ZP6 USSR Zone 5 6 hours 6 pm WAST West Australian Standard 7 hours 7 pm CCT China Co...

Страница 30: ... settings 6 4 4 IP Addressing IPV4 The 5073E T Switch needs to be assigned an IP address that identifies it on the network You can select a method of assigning IP address to the switch by choosing System IP Addressing IPV4 Figure 27 IPV4 Page DHCP Client Enable or disable the DHCP client function When the DHCP client function is enabled the switch will automatically obtain an IP address from the n...

Страница 31: ...ter the primary DNS IP address DNS2 Enter the secondary DNS IP address Apply Click to apply the settings 6 4 5 Syslog Syslog Configuration The Syslog system event log may be sent to the client only server only or both the client and server The type of events that are issued to the client or server depends on the system event selection on the System Alert Event page see System Alert Event To config...

Страница 32: ...rrent log Clear Clears the log contents 6 4 6 SNMP SNMP Agent Simple Network Management Protocol SNMP is the protocol developed to manage nodes for example servers workstations routers switches and hubs on an IP network SNMP enables network administrators to manage network performance find and solve network problems and plan for network growth Network management systems learn of problems by receiv...

Страница 33: ...bjects SNMPv3 Engine ID SNMPv3 engine ID value of the entity hosting the management information Each SNMPv3 agent has an engine ID that uniquely identifies the agent in the device and also provides unique identification of the MIB objects within a domain In SNMPv3 communication the engine ID is used as an identifier for an agent among different agents Apply Click to apply the settings SNMP Trap Co...

Страница 34: ...security and administration features and capabilities unique to this version The new security features include Confidentiality Packet encryption prevents snooping by an unauthorized source Integrity Message integrity ensures that a packet has not been tampered with while in transit This includes an optional packet replay protection mechanism Authentication Verfies that the message is from a valid ...

Страница 35: ...mation has been defined under a certain context by an SNMPv3 entity any management application can access that information by providing that context name Figure 32 SNMPv3 Context Tab Context Name Enter a name for the context table Apply Click to apply the setting The User tab allows you to add a user profile or remove an existing user profile Figure 33 SNMPv3 User Tab User ID Enter the name of the...

Страница 36: ...at appears in the Access tab Figure 34 SNMPv3 Group Tab Current Group Content List of existing groups and their associated user IDs To remove a group select the group and click Remove Security Name User ID User name of the user to be added to the group or removed from the group This must be a user name that you have set up in the User tab Group Name Name of the group to which the user is to be add...

Страница 37: ...ets are not encrypted AuthNoPriv User is authenticated Packets are not encrypted AuthPriv User is authenticated Packets are encrypted Context Match Rule Select the rule that will apply to a context match Exact Context name of a request must match the context prefix to access MIB views defined in this access profile Prefix Initial substring of the context name of a request must match the context pr...

Страница 38: ...he sub OID tree should be included with or excluded from the named view Add Adds the new MIB view Remove Removes the MIB view selected in the Current MIB Tables list 6 4 7 System Alert System Alert Relay Alarm The Fault Relay Alarm function provides power failure and port link down broken detection To configure this function choose System System Alert Relay Alarm For the power failure settings if ...

Страница 39: ...o turn on when the port link is down or broken Apply Click to apply the setting System Alert Event If the Syslog Mode is enabled on the Syslog Configuration page see 6 4 5 Syslog you can use the System Alert Event page to select which whether system restart power status and SNMP authentication failure events are sent to the Syslog server To display this page choose System System Alert Event NOTE I...

Страница 40: ...nput power to the switch becomes unstable SNMP Authentication Failure When enabled the system will issue an alert to the system log server when SNMP authentication fails Apply Click to apply the setting Digital Input Digital Output The 5073E T Switch contains two digital outputs and two digital inputs Outputs are open collector transistor switches that may be controlled by the host computer They p...

Страница 41: ... 1 1 Figure 40 Digital Output To set digital input and digital output triggers choose System System Alert DIDO to display the following page Figure 41 Digital Input Output Trigger Setting Digital Input Setting Enabling DI0 makes the first digital input available Enabling DI1 makes the second digital input available ...

Страница 42: ...output DO1 available Condition Select the checkboxes to specify whether events are sent via digital output for port fail power fail or both Action Choose the transition type Low High When switch receive the event about port fail or power fail DO0 DO1 will switch the output voltage from low to high High Low When switch receive the event about port fail or power fail DO0 DO1 will switch the output v...

Страница 43: ...200 Subnet Mask Enter the subnet mask of the IP configuration Gateway Enter the IP address of the gateway in your network DNS Enter the domain name server IP address in your network Lease Time Hour Enter the number of hours after which the client will reset the dynamic IP address Apply Click to apply the settings DHCP Server Client Table When the DHCP server function is enabled the system will col...

Страница 44: ...etting 6 5 Configure Menu 6 5 1 Port Port Configuration To configure the settings of each port to control the connection parameters choose Configure Port Configuration The status of each port is listed at the bottom of the page Figure 45 Port Configuration State Allows you to enable or disable the port When the port is disabled it will not receive or transmit packets ...

Страница 45: ...c Flow control is determined by auto negotiation and is only used when both linked ports have flow control enabled Asymmetric Flow control is always active regardless of whether the linked partner port is enabled Alias Allows you to add a description to let the manager know what device is connected to the port Auto Detect 100 1000 When enabled automatically detects the SFP module speed of the SFP ...

Страница 46: ...f good packets received via this port RX Bad Packet Number of bad packets received by this port Bad packets include undersized packets less than 64 octets oversized packets CRC errors fragments and jabber packets TX Abort Packet Number of packets aborted during transmission Packet Collision Number of packet collisions Packet Dropped Number of dropped packets RX Bcast Packet Number of broadcast pac...

Страница 47: ...m will only issue a log message when the link up event occurs for the port Link Down The system will only issue a log message when the link down event occurs for the port Link Up Link Down The system will issue a log message at the time when the port connection is link up or link down Disable No event will be sent to the system log Apply Click to apply the setting 6 5 2 Rate Control Rate Limit You...

Страница 48: ...t 1 Mbps is equal to 1024 kbps The range is from 100 kbps to 102400 kbps 100 Mbps for mega ports or 256000 kbps 250 Mbps for giga ports Zero indicates no egress rate limit Apply Click to apply the settings Storm Control Use this page to set the ingress rate limit and select what kind of frames are to be filtered by the ingress rate limit To display this page choose Configure Rate Control Storm Con...

Страница 49: ...s 6 5 3 Aggregation Aggregation Configuration Port trunking is the combination of several ports or network cables to expand the connection speed beyond the limits of any single port or network cable Link Aggregation Control Protocol LACP is a protocol running on layer 2 that provides a standardized means in accordance with IEEE 802 3ad to bundle several physical ports together to form a single log...

Страница 50: ... trunk The number of ports that carry traffic should be less than or equal to the number of ports selected for that LACP trunk If the number of work ports selected for the LACP trunk is less than the number of ports that belong to the LACP trunk the non working port s will remain idle and in standby In this configuration if a working port fails one of the non working ports will be brought in to ca...

Страница 51: ...st be a multiple of 4096 according to the protocol standard rule The root switch is responsible for recovering the backup path when it finds that switch connections have been broken for a period Max Age Enter the number of seconds that this device waits before checking to see if it should change to a different state Enter a value from 6 to 40 Hello Time Enter the time interval in seconds at which ...

Страница 52: ...ers Edge The edge port is directly connected to end stations and will not create a bridging loop in the network True Configures the port as an edge port False Configures the port as a non edge port Apply Click to apply the settings RSTP Information To display the port and switch information for RSTP choose Configure Spanning Tree RSTP Information Figure 54 RSTP Information Bridge ID The root switc...

Страница 53: ...ing states to the forwarding state 6 5 5 Redundancy Pro Ring2se To configure Pro Ring2se function on the 5073E T Switch choose Configure Redundancy Pro Ring2se For examples of Pro Ring2se connection options see 4 1 Pro Ring2se Application Figure 55 Pro Ring2se Pro Ring2se Protocol Enable or disable the Pro Ring2se function Mode Master Slave At least one switch must play the role of ring master swi...

Страница 54: ...switch know what VLAN group will be isolated with Control VLAN Enter all VLAN group IDs in this column except the control VLAN ID NOTE This is a required field Status Shows the current status of ring ports Ring State Complete The switch has Pro Ring2se topology enabled and the cable is installed Linkdown One or two of the port links are down Idle The switch is configured with Pro Ring2se topology ...

Страница 55: ...Figure 56 IGMP Snooping IGMP Snooping Enable or disable the IGMP protocol IGMP Query Enable or disable the IGMP query function The IGMP query information will be displayed in IGMP status section IGMP Unregister Stream Specify how the switch should process the IGMP unregistered stream Source Only IGMP unregister stream packets are sent to the source port from which those packets were received Block...

Страница 56: ... selected filter 6 5 7 LLDP Link Layer Discovery Protocol LLDP is defined in the IEEE802 1AB and is an emerging standard that provides a solution for the configuration issues caused by expanding LANs LLDP specifically defines a standard method for Ethernet network devices such as switches routers and wireless LAN access points to advertise information about themselves to other nodes on the network...

Страница 57: ...es or disables switch clock synchronization using LLDP Apply Click to apply the settings LLDP Neighbors The LLDP Neighbors page displays information about the port neighbors discovered using the LLDP protocol To display this page choose Configure LLDP LLDP Neighbors Figure 59 LLDP Neighbors 6 5 8 Filtering Data Base Filtering Data Base Configuration To configure the filtering data base choose Conf...

Страница 58: ...learned are connected to it Clicking Clear MAC Table will delete current list requiring that the port re learn the MAC addresses of its devices and rebuild the table Figure 61 Filtering Data Base Dynamic MAC Table Port No Select a port to view its MAC address table Current MAC Address Lists the MAC addresses of the devices connected to the selected port Clear MAC Table Clears the MAC address table...

Страница 59: ...with other devices Management LAN ID Set the VLAN group that can access the switch only ports with this VLAN ID can access the switch The default 0 means devices on all ports can access the switch Link Type There are four link types to choose from Access Link This link type only supports untagged VID The access link is a segment that provides the link path for one or more stations to the VLAN awar...

Страница 60: ...Q VLAN specification allows a single Virtual Local Area Network VLAN header to be inserted into an Ethernet frame QinQ allows multiple VLAN headers to be inserted into a single frame an essential capability for implementing Metro Ethernet network topologies In Metro Ethernet networks fewer IP v4 addresses are used by using QinQ A QinQ type VLAN can save IPv4 addresses by populating groups of sub V...

Страница 61: ...imply name the VLAN assign a VLAN ID and select the ports to be included in the VLAN Figure 63 VLAN Configuration Port based VLAN Step 1 Operation Mode Select Port Based to create a port based VLAN Add Click to add a new port based VLAN The screen in Figure 64 appears where you can configure the new VLAN Edit To edit a VLAN click the VLAN name in the list and click Edit The screen in Figure 64 app...

Страница 62: ... Assign a name to the VLAN VLAN ID Assign an identifier to the VLAN Add To add a port to the VLAN click the port in the left port column and click Add The port appears in the right column indicating that it is in the VLAN Remove To remove a port from the VLAN click the port in the left column and click Remove Apply Click to apply the settings VLAN Switch Status Use the Switch Status page to see th...

Страница 63: ... a strict priority scheme or select a priority type Figure 66 QoS Global Settings QoS Mode Select from the following modes or select Disable to turn off QoS Port Based The output priority is determined by the ingress port COS Only The output priority is determined by COS Class of Service only TOS Only The output priority is determined by TOS Type of Service only COS First The output priority is de...

Страница 64: ...t To display the QoS Port Priority page choose Configure QoS Port Priority Figure 67 Port Priority Priority Select a priority level high middle low or lowest Apply Click to apply the settings COS Mapping to Queue When QoS Mode field on the QoS Global Settings page is set to COS Only or COS First you can set the COS queuing policy for each port To set up COS mapping to queue choose Configure QoS Co...

Страница 65: ... each level When an IP packet is received the system will check the DSCP level value in the packet and grant it the appropriate priority For example if you set DSCP level 25 as High and system finds that the DSCP value of the received IP packet is 25 the packet will receive highest priority Apply Click to apply the settings 6 5 11 Port Mirroring Port mirroring is a method for monitoring traffic in...

Страница 66: ...rt will have its data duplicated and sent to the destination port Apply Click to apply the settings 6 6 Security Menu The Security function allows you to block unauthorized clients 6 6 1 IP Source Guard Configuration IP Source Guard allows you to limit the number of personnel authorized to manage the switch through HTTP and Telnet services by restricting access to ten IP addresses To configure thi...

Страница 67: ...P addresses in the Security IP1 IP10 table see the next section will be given permission to access this switch via SNMP service Apply Click to apply the settings Static Table The system allows you to assign up to ten IP addresses for access security When IP Security Mode is enabled on the IP Source Guard Configuration page only these ten IP addresses will be able to access and manage the switch th...

Страница 68: ...bled the configuration parameters become available Radius Server IP Assign the RADIUS server IP address Server Port Set the UDP destination port for authentication requests to the specified RADIUS server Accounting Port Set the UDP destination port for accounting requests to the specified RADIUS server Shared Key Set an encryption key for use during authentication sessions with the specified RADIU...

Страница 69: ...port To configure the port settings choose Security 802 1x Radius Port Settings Figure 74 802 1X Radius Port Setting Port Authorization Mode You can choose from the following authorization states Reject The specified port is required to be held in the unauthorized state Accept The specified port is required to be held in the authorized state Authorize The specified port is set to the Authorized or...

Страница 70: ...dress by switch choose Security MAC Filtering The MAC blacklist shows the list of MAC addresses that are currently blocked Figure 76 MAC Filtering MAC Address Enter a MAC address that you want add or delete from the MAC blacklist Addresses on the blacklist will be blocked by the switch Add Delete Click Add to add the address to the MAC blacklist or click Delete to remove the address from the MAC b...

Страница 71: ... you want add or delete from the Port Security List Addresses on this list will be allowed access to the port Port No Select a port number Add Delete Click Add to add the address to the Port Security List or click Delete to remove the address from the Port Security List 6 7 Maintenance 6 7 1 Save Configuration The Save Configuration page allows you to save the current switch settings To display th...

Страница 72: ...the option of keeping the current IP address username and password settings Figure 80 Factory Defaults 6 7 4 Firmware Upgrade The firmware upgrade software image for the 5073E T Switch can be obtained by contacting a Sales Representative To upgrade the firmware from a TFTP server or a website choose Maintenance Firmware Upgrade Click the tab for the upgrade method you want to use NOTE If you are u...

Страница 73: ...pgrade Click to upgrade to the new firmware 6 7 5 Export Import You can back up export the current configuration from flash ROM to the TFTP server or a local computer connected to the 5073E T Switch see Figure 83 You can also recover import a previous backup configuration to restore the settings see Figure 84 This saves having to manually reconfigure settings To use the export or import function c...

Страница 74: ...FTP server enter the TFTP server IP address and the backup file name and then click Backup in the upper part of the Export tab To export a configuration file to a local computer connected to the 5073E T Switch click Backup in the bottom part of the Export tab Figure 83 Export TFTP Server IP Address Allows you to back up the configuration file to the TFTP server Enter the TFTP server IP address Bac...

Страница 75: ...ton to locate the backup file and then click Restore in the bottom part of the Import tab Figure 84 Import TFTP Server IP Address Allows you to import a configuration file from a TFTP server Enter the TFTP server IP address Restore File Name Enter the file name to be restored Browse Allows you to import a configuration file from a local computer connected to the 5073E T Switch Click Browse to loca...

Страница 76: ...t value TX PWR Transmit power of the SFP default threshold and current value RX PWR Receive power of the SFP default threshold and current value Apply Click to apply the settings Refresh Click to refresh the page 6 8 Troubleshooting Follow these steps to troubleshoot switch problems 1 Verify that you are using the right power cord or adapter DC 12 48V WARNING Do not use a power adapter with DC out...

Страница 77: ...or does not turn on when the power cord is plugged in you may have a problem with power cord Check for loose power connections power losses or surges at the power outlet If you still cannot resolve the problem contact your local dealer for assistance 5 If the LED indicators are normal and the connected cables are correct but packets still cannot be transmitted check the configuration or status of ...

Страница 78: ...inouts With a 10 100BASE TX cable pins 1 and 2 are used for transmitting data and pins 3 and 6 are used for receiving data RJ 45 Pin Assignments Pin Number Assignment 1 Tx 2 Tx 3 Rx 6 Rx NOTE The and signs represent the polarity of the wires that make up each wire pair The following table shows the 10 100BASE TX MDI and MDI X port pin outs Pin Number MDI X Signal Name MDI Signal Name 1 Receive Dat...

Страница 79: ...et Switch User Manual 79 Rev Version 1 1 10 100 1000Base TX Pinouts Figure 89 shows the 10 100 1000 Ethernet RJ 45 pinouts Figure 89 10 100 1000 Ethernet RJ 45 Pinouts 10 100 1000Base TX Cable Schematic Figure 90 Straight through Cable Schematic Figure 91 Crossover Cable Schematic ...

Страница 80: ... 1815 8021x system accountport Port Number G Use the 802 1x system account port global configuration command to change the accounting port switch enable switch configure switch config 8021x system accountport1816 8021x system sharedkey SharedKey G Use the 802 1x system share key global configuration command to change the shared key value switch enable switch configure switch config 8021x system sh...

Страница 81: ...d to set the state of the selected port switch enable switch configure switch config interface fastethernet 3 switch config if 8021x portstate authorize show 8021x P Displays a summary of the 802 1xproperties and also the port sates switch enable switch show 8021x no 8021x G Disable 802 1x function switch enable switch configure switch config no 8021x Admin Password Commands CLI Commands Level Des...

Страница 82: ...tch disable configure P Enter Global Configuration mode switch enable switch configure end G Leave Global Configuration mode switch enable switch configure switch config end switch exit G Leave Global Configuration mode switch enable switch configure switch config exit switch DHCP Server Commands CLI Commands Level Description Example dhcpserver enable G Enable DHCP server switch enable switch con...

Страница 83: ...e switch show dhcpserver configuration show dhcpserver clients P Show client entries of DHCP server switch enable switch show dhcpserver clients show dhcpserver ip binding P Show IP Binding information of DHCP server switch enable switch show dhcpserver ip binding no dhcpserver G Disable DHCP server function switch enable switch configure switch config no dhcpserver Factory Default Command CLI Com...

Страница 84: ... G Configure last member query count switch enable switch configure switch config igmp last query count 1 igmp last query interval 1 250 tenths of a sec G Configure last member query interval switch enable switch configure switch config igmp last query interval 100 igmp query interval 1 250 sec G Configure query interval switch enable switch configure switch config igmp query interval 100 igmp que...

Страница 85: ...1 55 show security P Show the information of IP security switch enable switch show security no security G Disable IP security function switch enable switch configure switch config no security no security http G Disable IP security of HTTP server switch enable switch configure switch config no security http no security telnet G Disable IP security of Telnet server switch enable switch configure swi...

Страница 86: ...ig lldp synctime enable show lldp P Show LLDP information switch enable switch show lldp no lldp G Disable LLDP switch enable switch configure switch config no lldp Loading Average Commands CLI Commands Level Description Example loadavg E Show system load average switch loadavg event loadavg syslog G Set system load average event type switch enable switch configure switch config event loadavg sysl...

Страница 87: ...witch config mac address table filter hwaddr 000012348678 show mac address table filter P Show the MAC address table filter switch enable switch show mac address table filter no mac address table filter hwaddr HW Addr G Remove a MAC address entry from the table filter switch enable switch configure switch config no mac address table filter hwaddr 000012348678 Multicast Static Filtering Table Comma...

Страница 88: ... interface fastEthernet 2 switch config if duplex full speed 10 100 1000 auto I Use the speed configuration command to specify the speed mode of operation for fast Ethernet The speed cannot be set to 1000 unless the port is a giga port switch enable switch configure switch config interface fastEthernet 2 switch config if speed 100 flowcontrol mode symmetric asymmetric I Configure flow control swit...

Страница 89: ...source RX TX Both I Configure source port of monitor switch enable switch configure switch config interface fastEthernet 2 switch config if monitor source rx show monitor P Show port monitor information switch enable switch show monitor show monitor I Show port monitor information switch enable switch configure switch config interface fastEthernet 2 switch config if show monitor no monitor I Disab...

Страница 90: ...ormation switch enable switch configure switch config interface fastEthernet 2 switch config if no accounting Port Status Command CLI Commands Level Description Example show interface status I Show interface actual status switch enable switch configure switch config interface fastEthernet 2 switch switch config if show interface status Pro Ring2se Commands CLI Commands Level Description Example pr...

Страница 91: ... unicast frame switch enable switch configure switch config interface fastEthernet 2 switch config if ratelimit type broadcast multicast flooded unicast ratelimit type broadcast multicast I Set interface ingress limit frame type to accept broadcast and multicast frame switch enable switch configure switch config interface fastEthernet 2 switch config if ratelimit type broadcast multicast ratelimit...

Страница 92: ...to 1 200000000 I Path cost on this interface switch enable switch configure switch config interface fastEthernet 2 switch config if rstp path cost 20 rstp port priority 0 240 I Port priority on this interface switch enable switch configure switch config interface fastEthernet 2 switch config if rstp port priority 16 rstp admin p2p Auto True False I Admin P2P on this interface switch enable switch ...

Страница 93: ...ty strings public right ro snmp trap server IP address community Community string trap version v1 v2c G Configure SNMP server host information and community string switch enable switch configure switch config snmp trap server 192 168 1 120 community public trap version v2c snmp v3 user UserID password Authentication Password Privacy Password G Create a SNMPv3 user profile switch enable switch conf...

Страница 94: ...TP function is inactive this command cannot be applied Parameter format yyyymmdd hh mm switch enable switch configure switch config sntp daylight period 20120808 01 01 20120809 01 01 sntp daylight offset Minute G Set offset of daylight saving time If SNTP function is inactive this command cannot be applied switch enable switch configure switch config sntp daylight offset 60 show sntp P Show SNTP i...

Страница 95: ...ch config reload System Warning Commands CLI Commands Level Description Example syslog mode client server both G Specified the log mode switch enable switch configure switch config syslog mode both syslog ip IP address G Set system log server IP address switch enable switch configure switch config syslog ip 192 168 1 100 show syslog P Show SYSLOG configuration and log table switch enable switch co...

Страница 96: ... first G Setting of QoS priority type switch enable switch configure switch config qos prioritytype port base qos policy weighted fair strict G Select QoS policy scheduling switch enable switch configure switch config qos policy weighted fair qos priority portbased Port lowest low middle high G Configure port based priority switch enable switch configure switch config qos priority portbased 1 low ...

Страница 97: ...nfigure switch config aggregator activityport 1 2 aggregator group GroupID Port list nolacp G Assign a static trunk group GroupID 1 3 Port list Member port list This parameter can be a port range for example 1 4 or a port list separate by a comma for example 2 3 6 switch enable switch configure switch config aggregator group 1 2 4 nolacp or switch config aggregator group 1 3 1 2 nolacp show aggreg...

Страница 98: ...t 2 4 or switch vlan vlan port based grpname test grpid 2 port 2 3 4 show vlan GroupID or show vlan V Show VLAN information switch enable switch vlan database switch vlan show vlan 2 no vlan VID V Delete port base group ID switch enable switch vlan database switch vlan no vlan 2 IEEE 802 1Q VLAN vlan 8021q mnt vid VID V Configure management VID 0 is disabled switch enable switch vlan database swit...

Страница 99: ...ble switch vlan database switch vlan vlan 8021q port 3 hybrid link qinq untag 4 tag 3 6 8 or switch vlan vlan 8021q port 3 hybrid link qinq untag 5 tag 6 8 vlan 8021q aggreator GroupID access link untag UntaggedVID V Assign a access link for VLAN by trunk group switch enable switch vlan database switch vlan vlan 8021q aggreator 3 access link untag 33 vlan 8021q aggreator GroupID trunk link tag Tag...

Страница 100: ...Switch User Manual Rev Version 1 1 CLI Commands Level Description Example show vlan GroupID or show vlan V Show VLAN information switch enable switch vlan database switch vlan show vlan 2 no vlan GroupID V Delete port base group ID switch enable switch vlan database switch vlan no vlan 2 ...

Страница 101: ...by accessing a database maintained on a collection of Internet servers The program works behind the scenes to facilitate surfing the Web with alpha versus numeric addresses A DNS server converts a name like mywebsite com to a series of numbers like 107 22 55 26 Every website has its own specific IP address on the Internet DSCP Differentiated Services Code Point DSCP is a field in an IP packet that...

Страница 102: ...dware such as wireless cards is a security feature employed by closed wireless networks However an experienced hacker armed with the proper tools can still figure out an authorized MAC address masquerade as a legitimate address and access a closed network Every wireless 802 11 device has its own specific MAC address hard coded into it This unique identifier can be used to provide security for wire...

Страница 103: ...col used on the Internet or local area networks to provide a bidirectional interactive text oriented communication facility using a virtual terminal connection TFTP Trivial File Transfer Protocol TFTP is a file transfer protocol notable for its simplicity It is generally used for automated transfer of configuration or boot files between machines in a local environment Transmit Power The power usua...

Страница 104: ...5073E T Managed Ethernet Switch User Manual Rev Version 1 1 Term Definition Wi Fi Wireless Fidelity An interoperability certification for wireless local area network LAN products based on the Institute of Electrical and Electronics Engineers IEEE 802 11 standard ...

Страница 105: ...www cooperbussmann com wirelessresources Cooper Bussmann 5073E T Managed Ethernet Switch User Manual 105 Notes Rev Version 1 1 ...

Страница 106: ...7 US Fax 1 925 924 8502 Online Resources Visit www cooperbussmann com wirelessresources for the following resources and more User Manuals Installation Guides Configuration Software Datasheets Dimensional Drawings North America Latin America 5735 W Las Positas Suite 100 Pleasanton California 94588 USA Telephone 1 925 924 8500 elpro sales cooperindustries com Australia New Zealand Cooper Technology ...

Отзывы: