A 120V 60Hz single phase power connection on the
front
is required to supply power to
the light and the digital thermometer on all cooler sizes. Please, ask your Electrician to
refer to the wiring diagrams below to wire the Cooler Light and Thermometer.
•
A 115V 60Hz single phase power connection is required on the
back (or sides)
to supply
power to the A/C unit shipped with your Cooler (15KBTU or below ONLY)
•
A 230V 60Hz single phase connection is required on the
back (or sides)
to supply power
to the A/C unit shipped with your Cooler (18K or 24K BTU ONLY).
•
A 115V 50-60Hz single phase connection is required on the
back (or sides)
to supply
power to the CoolBot Digital controller.
LIGHT SWITCH AND LIGHT FIXTURE
Your Cooler may have one of these two types of switches:
Kason 1967-2
Kason 1967-3
(INDOOR Cooler
ONLY
)
(INDOOR or OUTDOOR Cooler)
OPERATION:
•
Turn on / off switch: Depress red rocker switch (1967-2) or touch yellow button (1967-3)
•
Depending on temperature of room will read:
▪
FrE
or F1 / F2 [-40°F to 30°F] or [-40°C to -1°C]
▪
CoL
or C1 / C2 [32°F to 50°F] or [0°C to 10°C]
▪
Hot
or H1/ H2 [ 75 -104°F] or [24°C to 40°C]
•
Temperature Units: Default °F, install small black jumper on the back of controller for °C
•
Errors / Warnings:
▪
Low battery (if connected):
"B"
on display will blink (replace battery)
▪
"
Hot
/ H1 / H2" room temperature is above 75°F
▪
"
OFF
" temperature probe is not connected (install, re-check connection, or replace
temp probe on the back of the controller)