Installing the water supply connection
1.
Flush the water connection on the on-site water line (Z).
2.
Install the sediment filter (X) and, if necessary, a water
treatment system (W).
3.
Install a separate shut-off device with a mesh strainer for
each unit (Y or Y
1
/Y
2
).
4.
Install an appropriate backflow preventer (V) in the water
supply line if required by local regulations.
5.
Connect the unit as shown in the ‘Connection drawing' on
6.
Flush the sediment filter under running water.
7.
Once you are done installing the water connection, close
the shut-off device.
8.
Inform the user of the maintenance intervals for the filters
and for the water treatment system (if any).
6 Installation
Installation Manual
47