6.5.2 Connecting the Fully Automatic Cleaning System
Rules for safely connecting the fully automatic oven cleaning system
Getting the ConvoClean and ConvoCare connections mixed up may pose a risk of injury or illness
when food cooked afterwards is eaten.
In order to prevent this risk, make sure to observe the following rules:
■
When connecting ConvoClean forte and ConvoCare, make absolutely sure that the hoses are con‐
nected to the right fitting and the right canister cap.
Prerequisites
■
Cold water connection as specified in the 'Water Supply' on page 45 section
■
Drain connection as specified in the 'Drain connection' on page 49 section
■
Technical prerequisites as specified in the 'Technical Data' on page 57 section
Connecting the fully automatic oven cleaning system with canisters
1.
F
4
5
2
1
3
G
3
Slip the green suction tube (2) for ConvoCare rinse aid
onto the barbed nipple on the rear bulkhead fitting (F) and
secure the tube using the wire hose clamp (3) (see
'Rinse-aid connection' adhesive label at the back of the
unit).
2.
Insert the suction nozzle on the green suction tube (2) in‐
to the rinse aid canister (1). The tube must be routed
without any kinks and the canister's vent opening must be
open and clear.
3.
Slip the red suction tube (4) for ConvoClean forte clean‐
ing agent onto the barbed nipple on the front bulkhead fit‐
ting (G) and secure the tube using the wire hose clamp
(3) (see 'Cleaning-agent connection' adhesive label at the
back of the unit).
4.
Insert the suction nozzle on the red suction tube (4) into
the cleaning agent canister (5). The tube must be routed
without any kinks and the canister's vent opening must be
open and clear.
5.
Start a cleaning sequence with the 1st setting and check
to make sure that cleaning agent is sprayed inside.
Optional customization
Optionally, an authorized service company, or the manufacturer, can customize the ConvoClean sys‐
tem as per the operator’s wishes (service manual).
6 Installation
Installation Manual