Obligations of Owners and Personnel with the Authority to Issue
Instructions in the Kitchen Area
Personnel working on the combi oven
The store manager or person with the authority to issue instructions must make sure that all transpor‐
tation, setup, installation, and removal-from-service work is carried out exclusively by qualified person‐
nel as described in 'Staff and Work Area Requirements.' on page 25
Personnel working on electrical systems
The store manager or person with the authority to issue instructions must make sure that all assembly,
placement-into-operation, servicing, maintenance, and repair work is carried our exclusively by quali‐
fied electricians.
Electrical assembly, placement-into-operation, servicing, maintenance, repair, and testing work on the
combi ovens must be carried out exclusively by authorized service companies in conformity with the
placement-into-operation, servicing, maintenance, and repair documents specified by Convotherm.
The required activities must be carried out exclusively by qualified electricians who have the required
training and current professional experience and who have the necessary familiarity with all applicable
standards, regulations, and accident prevention regulations.
Every qualified electrician performing assembly, placement-into-operation, servicing, maintenance, or
repair work must have read and understood the installation manual.
Rules for working on electrical systems
The combi oven must be electrically connected in conformity with all applicable regulations and gener‐
ally accepted standards and practices, as well as with the procedure outlined in the installation man‐
ual.
It is necessary to ensure that all electrical precautions, guards, and devices (mechanical and electri‐
cal) are being adhered to and are effective every time before the unit is put into operation, as well as
after any servicing, maintenance, or repair work. Moreover, this must be verified and documented by
means of measurements if required by applicable regulations.
Before being worked on, the unit must always be de-energized and locked and tagged out. In addition,
it is necessary to double-check that it has actually been de-energized properly.
After it has been established that the unit is properly de-energized, it is necessary to wait at least
15 minutes without exception in order to allow for the DC bus capacitors to be fully discharged.
In order to ensure operating and functional safety, all electrical connections must be checked, and all
required and mandatory electrical tests for placement into operation and regular operation must be
carried out.
Cybersecurity
The combi oven owner must make sure that the measures taken in order to ensure cybersecurity al‐
ways reflect the current state of the art.