Warning labels on combi oven case
Warning labels (2) on combi oven case:
Warning
Description
WARNING
To reduce the risk of electric shock, do not remove or open cover. No user
serviceable parts inside. Refer servicing to qualified personnel. Disconnect
power supply before servicing.
AVERTISSEMENT
Afin de réduire le risque d'électrocution, ne pas retirer ou ouvrir le capot. Au‐
cune pièce réparable ne se trouve à l'intérieur. Confier le dépannage à du
personnel qualifié. Débrancher l'alimentation électrique avant réparation.
CAUTION
Before commencing pluming installation refer to installation instruction fur‐
nished with unit.
DO NOT INSTALL a SHUTOFF ON DRAIN OUTLET
WARNING
Cancer and Reproductive Harm
www.p65Warnings.ca.gov
AVERTISSEMENT
Cancer et Troubles de l'appareil reproducteur
www.p65Warnings.ca.gov
Warnings in the combi oven wiring compartment
Warnings in the combi oven wiring compartment:
Warning
Description
WARNING
Field conversation from 3 PH to 1 PH is not permitted.
Warning labels on power cord
Warning labels (3) on the power cord:
Warning
Description
WARNING
Risk of Fire. Use only a UL listed grounding type attachment plug rated for:
■
208‑240 V, 30 AMP Minimum, 3 PH, 4 Wire
■
208‑240 V, 50 AMP Minimum, 3 PH, 4 Wire
■
208 V, 30 AMP Minimum, 3 PH, 4 Wire
■
240 V, 30 AMP Minimum, 3 PH, 4 Wire
■
208 V, 50 AMP Minimum, 1 PH, 3 Wire
■
240 V, 50 AMP Minimum, 1 PH, 3 Wire
The plug is to be selected and installed only by qualified service personnel
or electricians.
3 For Your Safety
Installation Manual
19