Figure 10-25 Menu 16 UD52 logic diagram
UD52 SINCOS small option module parameter list
3.26
Encoder 1
rpm
16.09
SINCOS encoder
phase offset
6
6
SIN in
SIN ref
COS in
COS ref
16.07
16.08
6
6
A(F)
/A(/F)
B(D)
/B(/D)
1
2
[16.07]
Simulated-encoder
F/D output enable
Simulated-encoder
output scaling
16.02
SINCOS
encoder rpm
16.11
SINCOS encoder
update
disable
16.03
SINCOS encoder
revolution count
16.04
SINCOS encoder
incremental
position (coarse)
16.05
SINCOS encoder
incremental
position (fine)
0.XX
0.XX
Key
Read-write (RW)
parameter
Read-only (RO)
parameter
Input
terminals
Output
terminals
The parameters are all shown at their default settings
6
SC data
SC data
16.14
SINCOS
as auxiliary
encoder
16.10
SINCOS encoder
phasing test
16.15
SINCOS encoder
voltage
select
16.12
SINCOS encoder
−
No. of lines per
revolution
16.13
SINCOS encoder
−
No. of revolutions
16.14
SINCOS as
reference encoder
16.16
SINCOS encoder
−
serial comms. disable
6
0V
5.15V
8.0V
Parameter
Range(
Ú
)
Default(
Ö
)
Type
OL
CL
OL
VT
SV
16.01
Option module code
0 to 100
4
RO Uni
P
16.02
SINCOS encoder rpm
±30,000 rpm
RO
Bi
P
16.03
SINCOS encoder revolution count
0 to 32,767 revolutions
RO Uni
P
16.04
SINCOS encoder position
0 to 16,383 revolutions/
16,384
RO Uni
P
16.05
SINCOS encoder position fine
0 to 255 revolutions/
4,194,304
RO Uni
P
16.06
SINCOS encoder 1 output select
0 or 1
0
RW Bit
16.07
SINCOS encoder output scaling
0 to 15 (power of 2)
0
RW Uni
16.08
F/D output select
0 or 1
0
RW Bit
16.09
Phasing offset
0 to 6143
RW Uni S
P
16.10
SINCOS encoder phasing test
0 or 1
0
RW Bit
16.11
Update disable
0 or 1
0
RW Bit
16.12
Number of encoder lines per revolution
256 (0), 512 (1),
1024 (2), 2048 (3),
4096 (4)
encoder lines per
revolution
512 (1)
RW Uni
16.13
Number of encoder turns
0 to 15 (power of 2)
0
RW Uni
16.14
SINCOS as auxiliary encoder
0 or 1
0
RW Bit
16.15
SINCOS encoder supply voltage select
0 or 1
0
RW Bit
16.16
Serial comms disable
0 or 1
0
RW Bit
16.17
Interpolation disable
0 or 1
0
RW Bit
RO
Read Only parameter
Uni
Unipolar variable parameter
R
Reset required for new value to take effect
Bi
Bipolar variable parameter
S
New parameter-value saved at power-down
RW
Read / Write parameter
Txt
Text variable parameter
P
Protected; forbidden as destination parameter
Bit
Bit parameter
FLC
Full-load current (max. continuous)