Figure 10-24 Menu 16 UD51 logic diagram
UD51 Second encoder small option module
parameter list
6
6
16.04
Second encoder
−
No. of lines per rev.
16.05
Second encoder
−
F/D input
enable
16.09
Second encoder
−
input termination
disable
Encoder AB and Z
(or F/D) inputs
6
A(F)
/A(/F)
B (D)
/B (/D)
Z
/Z
16.03
Second encoder
position
16.02
Second encoder
speed
3.27
Encoder 1
position
16.08
Second encoder
−
F/D output
enable
16.07
Encoder output
scaling
Encoder outputs
6
6
A(F)
/A(/F)
B(D)
/B(/D)
Freeze inputs or Z marker
pulse outputs from the
simulated encoder
16.11
Second encoder
−
Freeze input
termination
disable
16.10
Second encoder
−
Freeze input
enable
To UD70
Freeze encoder counts
Z marker pulse from
the simulated encoder
6
Z
/Z
0.XX
0.XX
Key
Read-write (RW)
parameter
Read-only (RO)
parameter
Input
terminals
Output
terminals
The parameters are all shown at their default settings
16.06
Encoder 1
output select
Parameter
Range(
Ú
)
Default(
Ö
)
Type
OL
CL
OL
VT
SV
16.01
Option module code
0 to 100
2
RO Uni
P
16.02
Encoder 2 input rpm
±30,000 rpm
RO
Bi
P
16.03
Encoder 2 position
0 to 16,384 revolutions/16,384
RO Uni
P
16.04
No. of Encoder lines / Pulses per rev
0 to 10,000 (F+D input, Pr
16.05
= 1)
0 to 5000 (Quadrature input, Pr
16.05
= 0)
1,024
RW Uni
16.05
Frequency input select
0 or 1
0
RW Bit
16.06
Encoder 1 output select
0 or 1
0
RW Bit
16.07
Encoder output scaling
0 to 15 (power of 2)
0
RW Uni
16.08
F/D output select
0 or 1
0
RW Bit
16.09
Encoder termination disable
0 or 1
0
RW Bit
16.10
Enable freeze input (disable Z output)
0 or 1
0
RW Bit
16.11
Disable freeze input termination
0 or 1
0
RW Bit
16.12
Encoder marker simulation
synchronisation disable
0 or 1
0
RW Bit
16.13
Encoder marker simulation
synchronisation inactive
0 or 1
RO Bit
P
RO
Read Only parameter
Uni
Unipolar variable parameter
R
Reset required for new value to take effect
Bi
Bipolar variable parameter
S
New parameter-value saved at power-down
RW
Read / Write parameter
Txt
Text variable parameter
P
Protected; forbidden as destination parameter
Bit
Bit parameter
FLC
Full-load current (max. continuous)