Menu 0
Running
the motor
Optimisation
Macros
Advanced
Parameters
Technical
Data
Diagnostics
UL Listing
Information
154
Unidrive User Guide
www.controltechniques.com Issue Number: 9
Parameter
Range(
Ú
)
Default(
Ö
)
Type
OL
CL
OL
VT
SV
9.01
Prog.-logic function 1 output
indicator
0 or 1
RO Bit
P
9.02
Prog.-logic function 2 output
indicator
0 or 1
RO Bit
P
9.03
Motorized pot. output
indicator
±100.0 %
RO Bi
S
P
9.04
Prog.-logic function 1 input 1 source
parameter
Pr
0.00
to Pr
20.50
Pr
0.00
RW Uni
P
9.05
Prog.-logic function 1 input 1
invert
0 or 1
0
RW Bit
9.06
Prog.-logic function 1 input 2 source
parameter
Pr
0.00
to Pr
20.50
Pr
0.00
RW Uni
P
9.07
Prog.-logic function 1 input 2
invert
0 or 1
0
RW Bit
9.08
Prog.-logic function 1 output
invert
0 or 1
0
RW Bit
9.09
Prog.-logic function 1 delay
0 to 25.0 s
0
RW Uni
9.10
Prog.-logic function 1 destination
parameter
Pr
0.00
to Pr
20.50
Pr
0.00
RW Uni R
P
9.14
Prog.-logic function 2 input 1 source
parameter
Pr
0.00
to Pr
20.50
0
RW Uni
P
9.15
Prog.-logic function 2 input 1
invert
0 or 1
0
RW Bit
9.16
Prog.-logic function 2 input 2 source
Pr
0.00
to Pr
20.50
Pr
0.00
RW Uni
P
9.17
Prog.-logic function 2 input 2
invert
0 or 1
0
RW Bit
9.18
Prog.-logic function 2 output
invert
0 or 1
0
RW Bit
9.19
Prog.-logic function 2 delay
0 to 25.0 s
0
RW Uni
9.20
Prog.-logic function 2 destination
parameter
Pr
0.00
to Pr
20.50
Pr
0.00
RW Uni R
P
9.21
Motorised pot. zero-start
select
0 or 1
0
RW Bit
9.22
Motorised pot. bipolar
select
0 or 1
0
RW Bit
9.23
Motorised pot. rate
0 to 250 s
20
RW Uni
9.24
Motorised pot. output scale factor
0 to 4.000
1
RW Uni
9.25
Motorised pot. destination
Pr
0.00
to Pr
20.50
Pr
0.00
RW Uni R
P
9.26
Motorised pot. up
0 or 1
RO Bit
9.27
Motorised pot. down
0 or 1
RO Bit
9.28
Motorised pot. reset
0 or 1
RO Bit
9.29
Binary-sum logic ones (MSB)
0 or 1
RO Bit
9.30
Binary-sum logic twos
0 or 1
RO Bit
9.31
Binary-sum logic fours
0 or 1
RO Bit
9.32
Binary-sum logic output value
0 to 7
RO Uni
P
9.33
Binary-sum logic destination parameter
Pr
0.00
to Pr
20.50
Pr
0.00
RW Uni R
P
RO
Read Only parameter
Uni
Unipolar variable parameter
R
Reset required for new value to take effect
Bi
Bipolar variable parameter
S
New parameter-value saved at power-down
RW
Read / Write parameter
Txt
Text variable parameter
P
Protected; forbidden as destination parameter
Bit
Bit parameter
FLC
Full-load current (max. continuous), Pr
11.32
{
0.33
}