![Control Techniques Unidrive 1 Series Скачать руководство пользователя страница 175](http://html.mh-extra.com/html/control-techniques/unidrive-1-series/unidrive-1-series_user-manual_2658692175.webp)
Safety
Information
Product
Information
Mechanical
Installation
Electrical
Installation
Getting
Started
Menu 0
Running
the motor
Optimisation
Macros
Advanced
Parameters
Technical
Data
Diagnostics
UL Listing
Information
Unidrive User Guide
175
Issue Number: 9 www.controltechniques.com
UD50 Additional I/O small option module parameter
list
Parameter
Range(
Ú
)
Default(
Ö
)
Type
OL
CL
OL
VT
SV
16.01
Option module code
0 to 100
1
RO Uni
P
16.02
Relay 2 output indicator
0 or 1
RO Bit
P
16.03
Relay 3 output indicator
0 or 1
RO Bit
P
16.04
Analog input 4
±100.0 %
RO
Bi
P
16.05
Analog input 5
±100.0 %
RO
Bi
P
16.07
Logic input F7 / Output 7 indicator
0 or 1
RO Bit
P
16.08
Logic input F8 / Output 8 indicator
0 or 1
RO Bit
P
16.09
Logic input F9 / Output 9 indicator
0 or 1
RO Bit
P
16.10
Logic input F10
0 or 1
RO Bit
P
16.11
Logic input F11
0 or 1
RO Bit
P
16.12
Logic input F12
0 or 1
RO Bit
P
16.13
Analog input 4 scaling
0.000 to 4.000
1.000
RW Uni
16.14
Analog input 4 invert bit
0 or 1
0
RW Bit
16.15
Analog input 4 destination
Pr
0.00
to Pr
20.50
Pr
0.00
RW Uni R
P
16.16
Analog input 5 scaling
0.000 to 4.000
1.000
RW Uni
16.17
Analog input 5 invert bit
0 or 1
0
RW Bit
16.18
Analog input 5 destination
Pr
0.00
to Pr
20.50
Pr
0.00
RW Uni R
P
16.19
DAC Output 3 source
Pr
0.00
to Pr
20.50
Pr
0.00
RW Uni R
P
16.20
DAC Output 3 scaling
0.000 to 4.000
1.000
RW Uni
16.21
F7 input destination / output source
Pr
0.00
to Pr
20.50
Pr
0.00
RW Uni R
P
16.22
F7 input/output invert
0 or 1
0
RW Bit
16.23
F7 output enable
0 or 1
0
RW Bit
R
16.24
F8 input destination / output source
Pr
0.00
to Pr
20.50
Pr
0.00
RW Uni R
P
16.25
F8 input/output invert
0 or 1
0
RW Bit
16.26
F8 output enable
0 or 1
0
RW Bit
R
16.27
F9 input destination / output source
Pr
0.00
to Pr
20.50
Pr
0.00
RW Uni R
P
16.28
F9 input/output invert
0 or 1
0
RW Bit
16.29
F9 output enable
0 or 1
0
RW Bit
R
16.30
F10 input destination
Pr
0.00
to Pr
20.50
Pr
0.00
RW Uni R
P
16.31
F10 input invert
0 or 1
0
RW Bit
16.32
F11 input destination
Pr
0.00
to Pr
20.50
Pr
0.00
RW Uni R
P
16.33
F11 input invert
0 or 1
0
RW Bit
16.34
F12 input destination
Pr
0.00
to Pr
20.50
Pr
0.00
RW Uni R
P
16.35
F12 input invert
0 or 1
0
RW Bit
16.36
Relay 2 source
Pr
0.00
to Pr
20.50
Pr
0.00
RW Uni R
P
16.37
Relay 2 output invert
0 or 1
0
RW Bit
16.38
Relay 3 source
Pr
0.00
to Pr
20.50
Pr
0.00
RW Uni R
P
16.39
Relay 3 output invert
0 or 1
0
RW Bit
16.40
Logic input polarity
0 or 1
0
RW Bit
R
P
16.41
Open collector outputs
0 or 1
0
RW Bit
R
P
RO
Read Only parameter
Uni
Unipolar variable parameter
R
Reset required for new value to take effect
Bi
Bipolar variable parameter
S
New parameter-value saved at power-down
RW
Read / Write parameter
Txt
Text variable parameter
P
Protected; forbidden as destination parameter
Bit
Bit parameter
FLC
Full-load current (max. continuous), Pr
11.32
{
0.33
}
Содержание Unidrive 1 Series
Страница 208: ......