4. Functions 

 

 

 

 

58

 

CNT-3204MT-LPE 

Abnormal input error 

An abnormal input error occurs when the counter input signal changes on the A and B phases 

simultaneously. Notification of the error is via a status (latch/clear), interrupt, or external output (one-

shot pulse). If the digital filter is enabled, an abnormal input error occurs when both the A and B phases 

change during one period of the digital filter source clock. When the filter is disabled, an abnormal input 

error occurs when both the A and B phases change during one period of the board 's 40MHz (25nsec) 
reference clock. 

A possible cause of the abnormal input error is as follows. 

When the phase difference between phases-A and B is shorter than one digital filter source clock 

cycle (25 nsec with no filter set) 

Noise is generated.

 

 

Figure 4.17. Abnormal input error

 

 

 

Phase-A input

Phase-B input

An abnormal input error is reported if phases-A and B

change in level during the filter source clock cycle.

No abnormal input error is reported when

the phase difference is longer than the

filter source clock cycle.

Filter source clock

Phase-A input

Phase-B input

Содержание CNT-3204MT-LPE

Страница 1: ...PC HELPER High Speed Up Down Counter Board for PCI Express Low Profile CNT 3204MT LPE User s Guide CONTEC CO LTD ...

Страница 2: ... missing items contact your retailer Product Configuration List Board CNT 3204MT LPE 1 First step guide 1 Disk 1 API PAC W32 1 Standard sized bracket 1 Warranty Certificate 1 Serial Number Label 1 1 The bundled disk contains the driver software and User s Guide this guide First step guide First step guide Serial Number Label Warranty Certificate Warranty Certificate Disk API PAC W32 Board Standard...

Страница 3: ...nge without notice All relevant issues have been considered in the preparation of this document Should you notice an omission or any questionable item in this document please feel free to notify CONTEC CO LTD Regardless of the foregoing statement CONTEC assumes no responsibility for any errors that may appear in this document or for results obtained by the user as a result of using this product Tr...

Страница 4: ...mation 5 Handling Precautions 6 Environment 7 Inspection 7 Storage 7 Disposal 7 2 SETUP 9 What is Setup 9 Using the Board under Windows Using the Driver Library API PAC W32 9 Using the Board under an OS Other than Windows 9 Step 1 Installing the Software 10 About the driver to be used 10 Step 2 Setting the Hardware 13 Replacing the Bracket 13 Parts of the Board and Factory Defaults 14 Setting the ...

Страница 5: ...ntrol input 34 Control input circuit and its sample connection 34 Connection of a control output 37 Control output circuit and its sample connection 37 4 FUNCTIONS 39 Types and Operations of Pulse Signals 39 Types of pulse signals 39 2 phase Input 39 Single phase Input 40 Single phase Input with Gate Control Attached 40 Multiplication of Count Input 41 Synchronous Clear 41 Asynchronous Clear 42 Ph...

Страница 6: ...l 59 Status input 60 Pulse signal input states 60 Control input signal states 60 Error 60 Carry Borrow 60 Count match 60 Other functions 61 Digital filter 61 Timer 61 5 ABOUT SOFTWARE 63 About Software for Windows 63 Accessing the Help File 63 Using Sample Programs 64 Uninstalling the Driver Libraries 65 6 ABOUT HARDWARE 67 For detailed technical information 67 Hardware specifications 67 Block Dia...

Страница 7: ...vi CNT 3204MT LPE ...

Страница 8: ...es The 32 bit up and down counter could have four channels and input the pulse signal at 10MHz maximum non insulation LVTTL level The minimum distinguishable phase of a two phase input is 25nsec A two phase signal such as a rotary encoder or a linear scale and a single phase signal can be counted One control signal input pin per channel counter start stop preset Supporting bus mastering can count ...

Страница 9: ...ed version please visit the CONTEC s Web site LabVIEW support data acquisition library DAQfast for LabVIEW DAQfast for LabVIEW Available for downloading free of charge from the CONTEC web site This is a data collection library to use in the LabVIEW by National Instruments With Polymorphic VI our design enables a LabVIEW user to operate seamlessly Our aim is for the customers to perform easily prom...

Страница 10: ... Screw Terminal M3 x 50P EPD 50A 1 3 Screw Terminal M3 x 68 EPD 68A 2 3 1 CNT 68M 50M optional cable is required separately 2 PCB68PS 0 5P or PCB68PS 1 5P optional cable is required separately 3 Spring up type terminal is used to prevent terminal screws from falling off Check the CONTEC s Web site for more information on these options ...

Страница 11: ...reight prepaid with a copy of the original invoice and a Return Merchandise Authorization to the distributor or the CONTEC group office from which it was purchased This warranty is not applicable for scratches or normal wear but only for the electronic circuitry and original boards The warranty is not applicable if the device has been tampered with or damaged through abuse mistreatment neglect or ...

Страница 12: ...destruction of equipment and resources Understand the meanings of these labels to operate the equipment safely DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION indicates a potentially hazardous situation which if not ...

Страница 13: ...e computer s power is turned on And also do not connect the board and external device while the power is turned on Otherwise the board may malfunction overheat or cause a failure Be sure that the personal computer or the I O extension unit power is turned off Make sure that your PC or extension unit can supply ample power to all the boards installed Insufficiently energized boards could malfunctio...

Страница 14: ...g this product keep it in its original packing form 1 Put the board in the storage bag 2 Wrap it in the packing material and then put it in the box 3 Store the package at room temperature at a place free from direct sunlight moisture shock vibration magnetism and static electricity Disposal When disposing of the product follow the disposal procedures stipulated under the relevant laws and municipa...

Страница 15: ...1 Before Using the Product 8 CNT 3204MT LPE ...

Страница 16: ... disk Driver Library API PAC W32 Taking the following steps sets up the software and hardware You can use the diagnosis program later to check whether the software and hardware function normally Step 1 Installing the Software Step 2 Setting the Hardware Step 3 Installing the Hardware Step 4 Initializing the Software Step 5 Operation Checks If Setup fails to be performed normally see the Setup Trou...

Страница 17: ...g information is focused on setting up API CNT WDM If you intend to use this product in the existing system where API CNT 98 PC is used continue to use API CNT 98 PC Please note that the API CNT 98 PC does not support Windows 8 or later and the 64 bit OS Use the API CNT 98 PC If you are installing from disk attachments select all from the Installer later in this chapter and starts the execution en...

Страница 18: ...ur PC 2 The API PAC W32 Installer window appears automatically If the panel does not appear run drive letter AUTORUN exe 3 Click on the Install Development or Execution Environment button Before installing the software in Windows 2000 or later log in as a user with administrator privileges CAUTION ...

Страница 19: ...r library 2 Select the Advanced Counter input driver 3 Click on the Install button Clicking the API CNT button under the Detail displays detailed information about API CNT WDM and API CNT 98 PC Run the installation 1 Complete the installation by following the instructions on the screen 2 The Readme file appears when the installation is complete ...

Страница 20: ...untouched You can change board settings later Replacing the Bracket This board is shipped with a Low Profile size bracket mounted To plug the board into a standard size slot replace the bracket with the bundled standard size bracket The replacing method is as follows Figure 2 1 Replacing the Bracket Use a flathead screwdriver or hexagonal spanner to undo and tighten the screws Remove the screws an...

Страница 21: ...ach of the boards to distinguish them The board IDs can be set from 0 to Fh to identify up to sixteen boards If only one board is used the original factory setting Board ID 0 should be used Setting Procedure To set the board ID use the rotary switch on the board Turn the SW1 knob to set the board ID as shown below Figure 2 3 Board ID Settings SW1 SW1 BOARD ID 0 1 2 3 4 5 6 7 9 A B C D E F 8 SW1 BO...

Страница 22: ...ise the board may malfunction overheat or cause a failure If the terminals are touched by someone s hands clean the terminals with industrial alcohol Do not install or remove the board to or from the slot while the computer s or extension unit s power is turned on Otherwise the board may malfunction overheat or cause a failure Be sure that the personal computer or the I O extension unit power is t...

Страница 23: ...cannot be properly installed unless the resources I O addresses and interrupt level for the board can be allocated Before attempting to install the board first determine what PC resources are free to use The resources used by each board do not depend on the location of the PCI Express bus slot or the board itself If you remove two or more boards that have already been installed and then remount on...

Страница 24: ...s to follow in performing installations on different Windows operating systems are included on the bundled disk so refer to the files in the following folder Help Hwinst Eng ApiTool chm 1 The Found New Hardware Wizard will be started Select No not this time and then click the Next button 2 When the model name of hardware is displayed select Install the software automatically Recommended and then c...

Страница 25: ...described in Step 4 To change the device name follow the setting procedure shown below Setting the device name 1 Run Device Manager From My Computer Control Panel select System and then select the Device Manager tab You can also open Device Manager by right clicking on My Computer and selecting Properties 2 The installed hardware appears under the CONTEC Devices node Open the CONTEC Devices node a...

Страница 26: ...e name you set here is used later when programming The initial device name that appears is a default value You can use this default name if you wish Make sure that you do not use the same name for more than one device You have now finished installing the initial setting of Software The name of the board you have just added is displayed CNT3204MT PE ...

Страница 27: ...been set up correctly Check Method Connect the board to a remote device to test the input output and check the execution environment Set the board in the default factory To connect an external device see Chapter 3 External Connection Starting the Diagnosis Program Open the Properties page of the device that was used for the software initialization and press the Diagnosis button ...

Страница 28: ...r mode settings Click on Counter Mode The Counter Mode setting dialog box appears 2 Set the counter mode for channel 0 Leave the other settings at factory defaults Click on Use Same Mode to make the same settings for the other channels Click on Counter Mode Click on Use Same Mode ...

Страница 29: ...2 Setup 22 CNT 3204MT LPE 3 Click on the End button to finish condition setting Click on End ...

Страница 30: ...used to check the basic operations of the counter Counter Start Starts the counter Zero Clear Clears the counter to zero Counter Stop Stops the counter 1 Click on Counter Start 2 The counter value of each channel is displayed along with its status ALM AI U A B Z Click on Counter Start ...

Страница 31: ...t pulse output The board has one test pulse output for phase A and another for phase B to check whether the counter inputs work normally The frequency of test pulse is fixed at 100 kHz The board can also internally output test pulses to each counter channel without supplying them to the outside In that case the board outputs two phase pulses to all channels at the same time Click on Start ...

Страница 32: ... board and channel settings and the diagnosis results as saved in text format The diagnosis program performed includes Board presence absence check interrupt test driver file test Board setting test Before executing diagnosis report output unplug the cable from the board CAUTION Click on Diagnosis Report ...

Страница 33: ...gram has been created using the driver API functions If the board works with the Diagnosis Program it will work with other applications Review the program paying attention to the following points Check the return values of functions Refer to the source code of sample program Refer to the Troubleshooting in API TOOL WDM HELP APITOOL chm The name of the board you have just added is displayed CNT 320...

Страница 34: ...ape and optional cable connection The on board interface connector CN1 is used when connecting this product and the external devices Please refer to chapter 1 for more information on the supported cable and accessories Figure 3 1 Interface connector CN1 and used connector Connector used 68 pin 0 8mm pitch connector HDRA E68LFDT HONDA TSUSHIN KOGYO CO LTD or equivalent Compatible connector HDRA E68...

Страница 35: ...nt Laminate side 150mm 1 35 2 36 33 67 34 68 Connector used 68 pin 0 8mm pitch connector HDRA E68MA1 HONDA TSUSHIN KOGYO CO LTD or equivalent Cable 68conductor Shield cable Cable length PCB68PS 0 5P 500mm PCB68PS 1 5P 1500mm Conductor size AWG 30 CNT 68M 50M PCA68PS P 50 49 27 26 25 24 2 1 Cable 68 conductor shielded cable Cable length 500mm Conductor size AWG 30 Cable 68 conductor shielded cable ...

Страница 36: ... 22 23 24 25 26 27 28 29 30 31 32 33 34 Ground Ground Ground Ground Unconnection Ground Ground Ground Ground Unconnection Ground Ground Ground Ground Unconnection Ground Ground Ground Ground Unconnection Ground Sampling start input Unconnection Ground Sampling start output Unconnection Test pulse Phase B output Unconnection CH1 control output 2 CH3 control output 2 Unconnection Control input signa...

Страница 37: ...4 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 3 3V Output 3 Counter Input signal pull up CH3 control output 2 CH1 control output 2 Test pulse Phase B output Sampling Start Output Ground Sampling Start Input Ground Ground Ground Ground Ground Ground Ground Ground Ground Ground Ground Ground Ground Ground Ground Ground Ground 3 3V Output 3 Counter Input ...

Страница 38: ...ct the counter input channel left unconnected For a two phase input connect both phase A and phase B For a single phase input connect to either phase A or phase B If not using the Z phase this does not need to be connected Remarks The pull up pins are PUP1 pin 32 1 for the counter input signal and PUP2 pin 66 1 for the control input signal PUP1 pin 32 Pull up for A B and Z phase input signal A0 B0...

Страница 39: ...er Counter Input Figure 3 7 Input signal The connection cable length should be within 1 5 m To prevent noise from causing a malfunction arrange the connection cable as away from any othersignal conductor or noise source as possible Please use the shielded cable to meet CE EMC Directive tPWL tPWH High level count input pulse width 50nsec Min tPWL Low level count input pulse width 50nsec Min tPWH CA...

Страница 40: ...et as the counter stop input the counter can be stopped at alarm output Pin numbers in the diagram shows those of connector on the board Figure 3 9 Example Connection with a Linear Scale channel 0 Shield Encoder GND 35 pin Connector pin No Phase A 1 pin Phase B 2 pin Phase Z 3 pin 3 3V output 34 pin Pull up 32 pin 0V Phase A Phase B Power supply Phase Z Shield Connector pin No GND 35 pin Control i...

Страница 41: ...oltage on output side IC If using 3 3V connect to the VCC pin on the board Not connecting the pull up voltage may affect the control input pin left unconnected Remarks The pull up pins are PUP1 pin 32 1 for the counter input signal and PUP2 pin 66 1 for the control input signal PUP1 pin 32 Pull up for A B and Z phase input signal A0 B0 Z0 A1 B1 Z1 A2 B2 Z2 A3 B3 Z3 PUP2 pin 66 Pull up for the cont...

Страница 42: ...on when it is pull up by internal 3 3 V output power Control input DI0 DI1 DI2 DI3 CLKIN STARTIN STOPIN The connection cable length should be within 1 5 m To prevent noise from causing a malfunction arrange the connection cable as away from any othersignal conductor or noise source as possible Please use the shielded cable to meet CE EMC Directive CAUTION ...

Страница 43: ...ignal Other control input signals DI0 DI3 EXTSTART EXTSTOP These signals are TTL level compatible and the trigger edge is software programmable at either the rising or falling edge High and low level hold times of at least 50 nsec are required to detect an edge of the signal Figure 3 13 Control input signals EXTCLK tPWH tPWH High level clock pulse width 50nsec Min tPWL Low level clock pulse width ...

Страница 44: ...ount match The signal is an LVTTL level output and can be set to positive or negative logic by software Control output circuit and its sample connection Figure 3 14 Sample connection to control output circuit DO0 DO3 CLKOUT STARTOUT STOPOUT Please use the shielded cable to meet CE EMC Directive Vcc Remote device Ground LVTTL level output TTL level input Internal circuit Board Vcc Ground CAUTION ...

Страница 45: ...3 External Connection 38 CNT 3204MT LPE ...

Страница 46: ...ar Multiply by 2 Single phase Input with Gate Control Attached Asynchronous Clear Multiply by 1 Single phase Input with Gate Control Attached Asynchronous Clear Multiply by 2 2 phase Input A two phase pulse input consists of two pulse inputs phase A advanced signal and phase B delayed signal with a phase difference of 90 If the Z phase reference position signal is used the two phase pulse input ca...

Страница 47: ...put Single phase Input with Gate Control Attached The counter can be started and stopped using a gate control signal input along with the single phase pulse stream Count operation for incremental counting in the CW direction When decremental counting in the CW direction is set the board performs decremental counting at the rising edges of the single phase pulse train phase A UP while the gate cont...

Страница 48: ...sing edge of the phase A signal after the phase Z input goes low When decremental counting in the CW direction is set the board performs decremental counting at the rising edge of the phase A signal while the phase B input remains low Figure 4 5 Example counting during synchronous clear A A B B UP DOWN A B When counterclockwise is specified During 2 phase input When clockwise is specified Single p...

Страница 49: ...hile the phase Z input remains low Figure 4 6 Example counting during asynchronous clear Phase Z CLR Input Phase Z is the signal to clear the counter to zero The number of phase Z inputs can be specified by software Figure 4 7 Phase Z enable frequency Positive logic The initial setting is only the next phase Z input is enabled once Phase Z negative logic is enabled while the phase Z input goes low...

Страница 50: ...nge low to high transition Available only when the control input signal has been selected for counter start stop Fall of control input signal The counter is ended at a level change high to low transition Available only when the control input signal has been selected for counter start stop Sampling stop Sampling stop counter stop 0 Software The counter is started or stopped by software either for e...

Страница 51: ... to Low Available only when the control input signal has been selected for presetting Count match Register0 Count value Comparison register 0 Count match Register1 Count value Comparison register 1 Software The counter is presetting by software either for each channel or for all channels Rise fall of an external input signal The counter is presetting by an external input signal supplied through th...

Страница 52: ...put The counter is zero cleared by the external phase Z input signal Software is used to select positive or negative logic and to enable or disable zero clearing Rise fall of an external input signal The counter is zero cleared by an external input signal supplied through the control input pin The control input pin is used for preset signal input The rising or falling edge of the signal can be sel...

Страница 53: ...tions such as reading the count value and status In addition this mode allows the board to preset zero clear start stop the counter at the rising or falling edge of the control input signal A one shop pulse can be output to the control input signal at an occurrence of a count match or error Figure 4 9 Timing chart Counter mode Is a sampling used Bus mastering is not used Only counter start stop is...

Страница 54: ...ampling see Sampling function described later in this chapter The counter start can be synchronized with the sampling start Figure 4 10 Timing chart Counter asynchronous sampling mode Figure 4 11 Timing chart Counter synchronous sampling mode Pulse input signal Samplingclock Count value 0 1 2 3 4 5 6 7 8 8 Nothing Sampling value 4 Counter start Counter stop Sampling start Sampling stop 4 Nothing 2...

Страница 55: ...erential counter mode the difference with the count at the previous sampling time is sampled A totalizing counter or differential counter can be setup for each channel Totalizing counter mode Line receiver counter mode Figure 4 12 Totalizing line receiver counter Pulse input signal Samplingclock Count value 0 1 2 3 4 5 6 7 8 9 Nothing 1 4 8 Sampling value Pulse input signal Samplingclock Count val...

Страница 56: ...n the physical address space However this product can still perform continuous data transfer to such discontinuous physical address spaces Bus master transfer can transfer data to physical address spaces up to 64Mbytes When setting up the transfer area in your application note that the actual available memory size depends on the operating system you are using and on the size of memory installed on...

Страница 57: ...ake appropriate action for example lower the transfer rate or system load S G OVER IN Indicates a buffer overflow The number of data items to be transferred exceeds the buffer size Increase the buffer size TRG ERROR Indicates that the external start and stop signals have been received Transfer is not performed when this status is set Check how the external start and stop signals are input CLOCK ER...

Страница 58: ...f external sampling stop signal EXTSTOP Count match When the count value for channel 0 3 matches the value in comparison register 0 or 1 Specified number of times Terminated after sampling for the specified number of times Bus master error When FIFO memory has become full Sampling can be controlled by one clock start and stop trigger per board One sampling start trigger per board and one sampling ...

Страница 59: ...t value Comparison register 1 Abnormal input error When phases A and B are changed at the same time Digital filter error When a pulse faster than the digital filter setting is input Count match Preset Count value Comparison register 0 Count value Comparison register 1 Zero clear Count value Comparison register 0 Count value Comparison register 1 1 When the control input signal is used as a general...

Страница 60: ...used as the general purpose input signal pin The input logic is fixed as positive logic Preset When the control input signal is set to presetting the control input pin serves as the external trigger input pin for presetting The rising or falling edge of the signal can be selected Zero clear When the control input signal is set to zero clearing the control input pin serves as the external trigger i...

Страница 61: ...tting is input The one shot pulse width is set by software to 10 µsec 100 µsec 1 msec 10 msec or 100 msec General purpose output When not used as a hardware event the control output pin can be used as a general purpose output In this case the output becomes a level output rather than a one shot pulse output The logic polarity can be switched between positive and negative Count match Register 0 A o...

Страница 62: ...rison register 0 or Count value Comparison register 1 Interrupt One shot pulse output Preset Zero clear Given below are application examples using the count match feature Example 1 Move count values 100 200 in both ways When the count value falls below 90 or exceeds 210 a one shot pulse is output to an external device Figure 4 13 Example 1 Initial setting External output signal selection Count mat...

Страница 63: ... Counter start 1 2 0 200 300 400 500 100 3 4 1 Time required between events About 5 ms depending on the system configuration 2 COMP0 Count match register 0 Status COMP1 Count match register 1 Status Event at 4 Count value 400 comparison register 1 A interrupt is occured with count value comparison register 1 Check the interrupt status and if COMP1 contains 1 set comparison register 1 to 600 Reset ...

Страница 64: ...tive times However a filter error does not occur if the frequency of the input clock is equal to or close to an integer multiple of the filer source clock The following are possible causes for a digital filter error When a signal faster than the digital filter setting is input Noise is generated Figure 4 16 Filter error Set to 0 2 µsec 0 0 0 0 0 0 0 0 0 0 0 0 1 0 1 0 1 0 1 0 1 0 1 0 1 1 0 0 0 0 1 ...

Страница 65: ... input error occurs when both the A and B phases change during one period of the board s 40MHz 25nsec reference clock A possible cause of the abnormal input error is as follows When the phase difference between phases A and B is shorter than one digital filter source clock cycle 25 nsec with no filter set Noise is generated Figure 4 17 Abnormal input error Phase A input Phase B input An abnormal i...

Страница 66: ...l 100nsec with negative logic polarity The logic polarity and pulse width cannot be modified Sampling stop output signal This outputs the sampling stop trigger as a one shot pulse signal 100nsec with negative logic polarity The logic polarity and pulse width cannot be modified Sampling clock output signal This outputs the sampling clock trigger as a one shot pulse signal 100nsec with negative logi...

Страница 67: ...aneously A status is latched to indicate that this error has occurred and can be cleared by software Digital filter error When a signal faster than the digital filter setting is input to phase A or B it is reported as a digital filter error The status is latched and cleared by software Carry Borrow Carry The 32 bit counter is set to 1 when incremented from its maximum value FFFFFFFFh 0h Borrow The...

Страница 68: ...s required for them to be input when the digital filter is used Initially the delay owing to the digital filter does not occur as it is not used by default Figure 4 18 Digital filter The digital filter is initially disabled It remains disabled when left untouched The delay may be longer than the set time depending on the noise included If the level changes at a frequency shorter than the set time ...

Страница 69: ...4 Functions 62 CNT 3204MT LPE ...

Страница 70: ...ion to output a one shot pulse to the control output signal upon detection of a count match or error Function to sample count values using bus mastering in sync with the specified external clock or internal clock For details refer to the help file Accessing the Help File The method to use in accessing the help file varies slightly depending on the version of the driver the development environment ...

Страница 71: ... the list of CONTEC API CNT WDM 3 A sample program is invoked Sample program of API CNT WDM Counter Sample Counter Set various counter programs and perform them Counter Counter 1 Perform counters by the device containing bus master transfer function which sets the various settings CounterCallback CounterCallback 1 Perform counters by callback Sampling Sampling 1 Execute sampling for one transfer I...

Страница 72: ...ght clicking on My Computer and selecting Properties Select Windows Driver Package CONTEC and then click Change Remove contains the driver category name caio ccnt cdio csmc etc Uninstall the development environment Use My Computer Control Panel Programs and Features to uninstall the development environment In case of API WDM select CONTEC API WDM VerX XX Develop and then click Uninstall contains t...

Страница 73: ...5 About Software 66 CNT 3204MT LPE ...

Страница 74: ...A UP 1 x 4 channels Phase B DOWN 1 x 4 channels Phase Z CLR 1 x 4 channels Response frequency 10MHz 50 duty Digital filter 0 1µsec 1 6384msec or not used can be independently set for each channel Timer 1msec 6553msec 1msec unit Counter start trigger Software External start input Sampling start trigger Counter stop trigger Software External stop input Sampling stop trigger Sampling Sampling start t...

Страница 75: ...t pulse output General purpose output Level output Software selected from among the above five options Positive negative logic is selected with the software One shot output signal amplitude Selected between 10µsec 100µsec 1msec 10msec and 100 msec Can be set for each channel within precision 1µsec Response time 100nsec Max Rated output current IOL 8mA Max IOH 8mA Max Test pulse Test pulse output s...

Страница 76: ...condensation Bus specification PCI Express Base Specification Rev 1 0a x1 Dimension mm 121 69 L x 67 90 H Connector used 68 pin 0 8mm pitch connector HDRA E68LFDT HONDA TSUSHIN KOGYO CO LTD or equivalent to it Weight 60g Standard VCCI Class A CE Marking EMC Directive Class A RoHS Directive 1 Please use the shielded cable to meet CE EMC Directive Board Dimensions mm 121 69 L 67 90 H The standard ou...

Страница 77: ...ogic FIFO CH0 Command setting register Counter read register 32 bit counter Initial value storage register Comparison setting register Signal selector digital filter Each control register Sampling control CH2 External control signal Direct Read Unisolated LVTTL level signal input PC I Bus Interface ...

Страница 78: ......

Страница 79: ...31 Himesato Nishiyodogawa ku Osaka 555 0025 Japan https www contec com No part of this document may be copied or reproduced in any form by any means without prior written Consent of CONTEC CO LTD 08252017 03172006 Management No A 51 232 08252017_rev5 Parts No LYGB885 ...

Отзывы: