4. Functions
CNT-3204MT-LPE
53
Control input signal
One control input signal is provided for each channel. The control input signal can serve for one of the
following applications. The application is software-selectable.
Table 4.7. Control input signal
Item
Purpose
Condition
Control
input signal
General-purpose input
Software status(positive logic)
Preset
Rise (Low → High)
Fall (High → Low)
Zero-clear
Rise (Low → High)
Fall (High → Low)
Counter start/stop
Rise (Low → High)
Fall (High → Low)
General-purpose input
When not used for a hardware event, the control input pin can be used as the general-purpose input
signal pin. The input logic is fixed as positive logic.
Preset
When the control input signal is set to presetting, the control input pin serves as the external trigger
input pin for presetting. The rising or falling edge of the signal can be selected.
Zero-clear
When the control input signal is set to zero-clearing, the control input pin serves as the external trigger
input pin for zero-clearing. The rising or falling edge of the signal can be selected.
A counter start/stop
When the control input signal is set to counter start/stop, the control input pin serves as the external
trigger input pin for counter start/stop. The rising or falling edge of the signal can be selected for each of
the counter start and counter stop.
Содержание CNT-3204MT-LPE
Страница 7: ...vi CNT 3204MT LPE ...
Страница 15: ...1 Before Using the Product 8 CNT 3204MT LPE ...
Страница 29: ...2 Setup 22 CNT 3204MT LPE 3 Click on the End button to finish condition setting Click on End ...
Страница 45: ...3 External Connection 38 CNT 3204MT LPE ...
Страница 69: ...4 Functions 62 CNT 3204MT LPE ...
Страница 73: ...5 About Software 66 CNT 3204MT LPE ...
Страница 78: ......