9
Intermediate module
Dimension
(mm)
Descrip-
tion
1 500
D
2 007
E
2 060
F
630
G
Pressure loss
No� Modules
Flow
Unit
2
3
4
5
6
5m³/h
mbar
33
22
21
21
21
10 m³/h
mbar
130
92
82
82
82
15m³/h
mbar
292
212
183
180
180
Pressure drop when flowing through
of 3 modules (measurement: ITW)
NOTE:
When connecting both sides of
the store and more than 3 modules
larger flow rates at the same
pressure loss are possible. In parallel use of two
Connections on different heights
a higher flow rate is also possible
4�3 Minimum room sizes for module installation
Profile rails
Insulation
End module
Dimension
(mm)
Descrip-
tion
1 565
H
2 020
I
2 050
J
693
K
Minimum depth
A (cm)
Length of loading and dis-
charge charge tube (cm)
2 modules
278
134
3 modules
340
197
4 modules
403
260
5 modules
466
323
6 modules
529
197
7 modules
592
260
8 modules
655
323
When assessing access note the lengths of pipe.
Recomended value Min. value for assembly*
B: Room width
ca� 350 cm
ca. 290 cm
C: Recommended clearance lateral wall to
store without insulation
ca� 100 cm
ca. 50 cm
D: Minimum longitudinal wall to store
distance without insulation
ca� 70 cm
s. l.
E: Minimum longitudinal wall to store
distance with insulation
ca� 44 cm
s. l.
F: Lateral distance to wall from store with
insulation (at C = 100 cm)
ca� 82 cm
ca. 52 cm
(bei C = 290 cm)
Minimum room height for insulated modules
ca� 217 cm
s. l.
* Accessibility for connections, maintenance, etc. not included.
0
50
100
150
200
250
0
2.500
5.000
7.500
10.000
12.500
15.000
Pressure loss in mba
Volume Flow in l/h
Pressure loss Store without
connections (measured)
Pressure loss Store without
connections (extrapolated)
Values calculated on the basis of measured values for 3 modules and up to approx. 6 m
3
/h.
T D M A - VA R I C A L :
Technical Data