12
5�3 Hot water
Hot water preparation via central fresh water station. With
secondary recirculation divert the warm return to the middle
of the buffer.
Follow the manufacturers instructions.
Fresh water station, divert valve for the recirculation mode
DHW storage from central buffer
5�2 Integration of heat generator
Notes on the integration of different heat generators:
• Flow hot water / heating depending on the system at the
appropriate height connection
• Return without solar at the bottom
• Observe information from the boiler manufacturer
• Return protection depending on the boiler maybe necessary to
prevent sooting. Follow the manufacturers instructions.
Modulating condensing boiler
Return protection, soot prevention
External electric heating source
CI
FL DHW
FL HTG
T D M A - VA R I C A L :
Hydraulic plans