Installation Manual
Spring Cable Reel
BEF150 – BEF500
MAL6100-0001a-EN
www.conductix.com
translated document
Page 38 of 54
DANGER!
Danger of fatal injury from pretensioned drive springs!
The drive springs are installed in protective metal housings for protection from injury. If the
protective housings are opened, then the drive springs (coils of spring steel) can be released
from the protective housing in an uncontrolled manner. This can cause severe cuts and
impact injuries that could even be fatal.
→
Do not open the protective housing!
→
Replace springs only as a complete unit with the protective housings!
DANGER!
Danger of death due to hanging loads!
When lifting loads, there is a danger of death from falling parts or those swinging out of
control.
→
Never step under hanging loads
→
Follow the specifications for the attachment points provided
9.3.1
Prerequisites
Disconnect all cables from power and secure against being turned back on.
Disconnect the mobile cable from the feed point (= attachment point) and wind it onto the reel body. Release the springs
slowly and completely during this process.
Remove the mobile cable from the reel.
Unscrew and remove the housing of the slip ring body.
Disconnect the fixed feed cable from the slip ring body and pull it out through the central axis.
The complete cable must be removed.
Remove the complete reel from the device.
9.3.2
Series connection
Spring designation, e.g.: 2DH (T) H or 2UA (T)H [H for series connection]
9.3.2.1
Dismantling
→
Loosen the threaded pin [1] of the fastening flange.
→
Pull off the flange [2], V-ring [3] and spacer [4].