Installation Manual
Spring Cable Reel
BEF150 – BEF500
MAL6100-0001a-EN
www.conductix.com
translated document
Page 34 of 54
9
Service
9.1
Safety
WARNING!
Danger of death by electrocution!
Contact with components carrying electrical power can lead to death or severe injury by
electrocution. Danger of injury due to shock reactions, falling, or being thrown away due to
electrical shock.
→
Before starting electrical connection work, disconnect all relevant cables from power and
secure the device or system against being turned back on
→
Follow the five safety rules!
→
Earth the device on the earthing connection (PE) of the slip ring body
9.2
Service intervals and maintenance work
Have an electrician carry out an inspection after no more than one year. If the strain is unusually high, the electrician must be
called earlier.
9.2.1
Reel
→
Check all bolts and nuts for firm seating, since all reels are assembled from individual parts.
→
Check all rubber seals and cable collars for tightness and/or damage.
→
If necessary, replace rubber seals or cable collars.
Flange
→
Check the connection between the flange and axis for firm seating.
Clean the slip ring body
Protective equipment needed:
CAUTION!
Danger of sensitization, mucous membrane irritation and respiratory disease due to dust!
Abrasion residue from the carbon brushes collects in the slip ring body. This dust is very fine and is
a health hazard.
→
During cleaning, wear personal protective equipment:
•
Safety goggles
•
Dust mask, class FFP3
→
Do not blow out dust with compressed air but rather vacuum it away. The vacuum cleaner
must be equipped with a class H fine filter
→
Do not eat, drink or smoke during work!