Fig. 8 Cable connections on the slip ring body
Connecting the reel cable:
→
Remove slip ring body hub.
→
Guide the mobile cable (= reel cable) through the slot in the outer round plate and into the collar in the lower part of the hub in
the slip ring body.
→
Connect the reel cable to the current collectors of the slip ring body.
→
The cable may not contact the slip ring body within the slip ring body housing!
→
Tighten the cable collars to relieve tension.
Overview of current collector variants:
Current collectors
Connection material to be used
Type 45
Blade receptacle 6 3x0.5 (see Fig. 9)
Type 13
M5 cable shoe (see Fig. 10)
Type 15
M6 cable shoe (see Fig. 10)
Type 16
M8 cable shoe (see Fig. 11)
Type 18
M4 cable shoe (see Fig. 12) or insulated blade receptacle 6 3x0.5
Type 19
M8 cable shoe (see Fig. 11)
CAUTION!
Terminal diagram
→
Follow the attached terminal diagram for connection work.
Cable connections,
earth, feed
Cable connections,
reel cable