Installation of the connector box
Upon delivery the box is ready to be connected. Use the provided fasten-
ing material (
4 pan head screws M5x55 mm, 4 spring washers M5
, and
4 blind nuts M5
) to mount the connector box directly to the ventilation duct/
monobloc or to a frame.
Before mounting the connector box,
read the notes on correct location
and make sure the
length of the water hoses
between the connector box
and the nozzles is as short as possible (
max. 10 m
).
Installation of the silver ionization unit
Use the provided fastening material (
2 pan head screws M6x25 mm,
2 spring washers M6
, and
2 blind nuts M6
) to mount the silver ionization
unit directly to the ventilation duct/monobloc or to a frame.
Before mounting the silver ionization unit,
read the notes on correct loca-
tion
and make sure the length of the
water hoses
to the connector box
and the booster pump is as short as possible (
max. 10 m
).
Installation of the booster pump
At the factory the booster pump is fastened to a mounting plate and is
therefore ready to be connected as supplied. Use the provided fastening set
(
4 round head wood screws ø8x50 mm
, and
4 plugs ø10 mm
) to fasten
the mounting plate to a wall, a pillar, or another suitable surface.
Before mounting the booster pump,
read the notes on correct location
and make sure the length of the
water hoses
between the pump and the
connector box is as short as possible (
max. 20 m
).
Installation of the control unit
Use the provided fastening material (
2 pan head screws M5x35 mm, 1 pan
head screw M5x25 mm, 3 spring washers M5
, and
3 blind nuts M5
)
to mount the control unit directly to the ventilation duct/monobloc or to a
frame.
Place the control unit close to the humidification unit. Before mounting the
control unit,
read the notes on correct location
and make sure the length
of the
electrical wiring
to the connector box, the booster pump, and the
silver ionization unit is
as short as possible
.
125 mm
85 mm
40 mm
640 mm
900 mm
ø10 mm
ø8x50 mm
138 mm
240 mm
138 mm
M5x55
M6x25
M5x25
M5x35
M5x35