7 . 1 K n i f e c h a n g i n g
( c o n t i n u e d )
2
Lift out and mark each support rule together with the knife to the fixed knife pair.
3
Clean the knife positions where the knives were located.
Fixed knife no. 3 (rear upper, option)
1
Noise encapsulated machine, loosen and remove the protective plate on rear
side of the granulator.
2
Undo and remove the socket cap screws which fasten the support rules and the
fixed knife pair (hex 17 mm).
The socket cap screws which fasten the support rules and the fixed knife pair,
are undone from rear side of the cutter housing.
3
Mark and lift out the support rules to the fixed knife pair.
4
Mark and lift out the fixed knife pair.
5
Clean the knife positions where the knives were located.
Fixed knife no. 4 (front upper, option)
1
Undo and remove the socket cap screws which fasten the support rules and the
fixed knife pair.
The socket cap screws which fasten the support rules and the fixed knife pair,
are undone from outside of the cutter house door.
NOTE:
The fixed knife and the support rules are heavy, be careful!
2
Mark and lift out the support rules.
3
Mark and lift out the fixed knife pair.
4
Clean the knife positions where the knives were located.
7 - 8
l S e r v i c e