5 - 1 6
l M a i n t e n a n c e
5 . 8 C l o s e t h e s c r e e n b o x , g r a n u l e
b i n , c u t t e r h o u s e d o o r a n d h o p p e r
( c o n t i n u e d )
Install the granule bin
3
1836 and 1848 Fit the distribution plate in
correct direction inside the granule bin.
4
Install the granule bin “E”. Take a firm two-
hand grip on the granule bin, lift and slide the
granule bin in on the guides on screen box.
NOTE:
Push in the
granule bin firmly to stop.
Close the hopper
The hopper is closed by an electrical jack.
The jack is located inside the granulator.
4
Plug in the granulator connector to the main power supply.
5
Set the main power switch to position “1” On.
6
Reset the emergency stop knob.
7
NOTE:
The cutter house door must be opened, to enable the hopper to be closed.
– The safety switch by the granule bin checks that the cutter house door is opened.
8
The operation buttons for closing the hopper are located on the electrical cabinet.
– Set the knob “Hopper close/open” to “Close”.
The closing is two-hand controlled for safety reasons.
– Ensure that the lamps in both of the buttons “Hopper operate I” and ”Hopper
operate II” lights.
– Press the buttons “Hopper operate I” and ”Hopper operate II” simultaneously .
to close the hopper.
A limit switch senses and stops the closing action when the hopper is fully
closed.
– When the hopper closes, the cutter lock opens mechanically to release the
cutter.