LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC)
MN-LPOD
Serial Interface Operation
Revision 14
5–16
Parameter Type
(* indicates
End-of-Life)
Controller-to-Target
Instruction Code and
Qualifier
Arguments for
Command or
Query
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
Target-to-Controller
(see Description of Arguments)
Command
Query
Response to
Command
Response to
Query
Set RTC Date (by
Day)
DAY=
DAY?
6 bytes
Command or Query.
Sets or returns the Reasl-Time-Clock date in the form ddmmyy, where:
dd=day of the month (01 to 31)
mm=month of the year (01 to 12)
yy=year (00 to 99) (2000 to 2099)
COMMAND EXAMPLE (date=April 25, 2016):
<0001/DAY=250416{CR}
DAY=
DAY?
DAY*
DAY=ddmmyy
Enable Statistics
Averaging
ESA=
ESA?
1 byte
Command or Query.
Enables or Disables averaging of statistics data, at a rate of once per second every 10 seconds, in the form x,
where:
0=Disable
(DEFAULT – SEE NOTE)
1=Enable
NOTE:
If Disabled, burst values will be logged instead of averaged values.
COMMAND EXAMPLE:
<0001/ESA=0{CR}
ESA=
ESA?
ESA*
ESA=x
Enable Statistics
Logging
ESL=
ESL?
1 byte
Command or Query.
Sets or returns the statistics logging function in the form x, where:
0=Disable
(DEFAULT)
1=Enable
COMMAND EXAMPLE:
<0001/ESL=1{CR}
ESL=
ESL?
ESL*
ESL=x
Enable
Redundancy
Switch Mode
ESW=
ESW?
1 byte
Command or Query.
Sets or returns the redundancy state in the form x, where:
0=Off
(DEFAULT)
1=1:1 Redundancy Tx (Only Tx switch installed)
2=1:1 Redundancy Tx + RX (Tx and RX switch installed)
5=1:1 Manual redundancy mode (used for debugging, or redundancy system setup)
(SEE NOTE)
NOTE:
Manual redundancy does not support automatic switching, and the offline unit will not poll the online unit
to update its configuration.
COMMAND EXAMPLE:
<0001/ESW=1{CR}
ESW=
ESW?
ESW *
ESW=x
Содержание LPOD
Страница 4: ...ER LPOD EB14 Rev PLM C 0036842...
Страница 52: ...LPOD C X or Ku Band Outdoor Amplifier Block Up Converter BUC MN LPOD Introduction Revision 14 1 28 Notes...
Страница 92: ...LPOD C X or Ku Band Outdoor Amplifier Block Up Converter BUC MN LPOD Firmware Update Revision 14 3 16 Notes...
Страница 177: ...LPOD C X or Ku Band Outdoor Amplifier Block Up Converter BUC MN LPOD Appendix A Revision 14 A 15 BLANK PAGE...
Страница 181: ...LPOD C X or Ku Band Outdoor Amplifier Block Up Converter BUC MN LPOD Appendix A Revision 14 A 19 BLANK PAGE...
Страница 185: ...LPOD C X or Ku Band Outdoor Amplifier Block Up Converter BUC MN LPOD Appendix A Revision 14 A 23 BLANK PAGE...
Страница 189: ...LPOD C X or Ku Band Outdoor Amplifier Block Up Converter BUC MN LPOD Appendix A Revision 14 A 27 BLANK PAGE...
Страница 193: ...LPOD C X or Ku Band Outdoor Amplifier Block Up Converter BUC MN LPOD Appendix A Revision 14 A 31 BLANK PAGE...
Страница 197: ...LPOD C X or Ku Band Outdoor Amplifier Block Up Converter BUC MN LPOD Appendix A Revision 14 A 35 BLANK PAGE...
Страница 201: ...LPOD C X or Ku Band Outdoor Amplifier Block Up Converter BUC MN LPOD Appendix A Revision 14 A 39 BLANK PAGE...
Страница 205: ...LPOD C X or Ku Band Outdoor Amplifier Block Up Converter BUC MN LPOD Appendix A Revision 14 A 43 BLANK PAGE...
Страница 213: ...LPOD C X or Ku Band Outdoor Amplifier Block Up Converter BUC MN LPOD Appendix A Revision 14 A 51 BLANK PAGE...
Страница 219: ...LPOD C X or Ku Band Outdoor Amplifier Block Up Converter BUC MN LPOD Appendix A Revision 14 A 57 BLANK PAGE...
Страница 231: ...LPOD C X or Ku Band Outdoor Amplifier Block Up Converter BUC MN LPOD Appendix B Revision 14 B 9 BLANK PAGE...
Страница 234: ...LPOD C X or Ku Band Outdoor Amplifier Block Up Converter BUC MN LPOD Appendix B Revision 14 B 12 Notes...
Страница 249: ......
Страница 250: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...