HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier
Revision 9
Serial-Based Remote Product Management
5–22
MN/HPOD.IOM
Parameter
Type
Command
(Instruction
& Qualifier)
Number of
Arguments
Description of Arguments
Response to
Command
Query
(Instruction &
Qualifier)
Response to
Query
Remote
Baud Rate
SBR=
4 bytes,
alphanumeri
c
Command or Query.
Set remote baud rate in the form xxxx, where:
9600 = 9600 baud
19K2 = 19200 baud
Example:
SBR=9600’cr’
Note:
When changing baud rates remotely the response to the
command will be returned using the same baud rate as that used
to send the command.
SBR=
SBR?
SBR?
SBR=xxxx
(See
Description of
Arguments)
Summary
Fault Status
N/A
1 byte,
value of 0,1
Query only.
Returns the condition of the summary fault relay where:
0 = Not Faulted (SumFLT_COM J6 pin K is connected to
SumFLT_NO J6 pin L, and SumFLT_NC J6 pin M is open)
1 = Faulted (SumFLT_COM J6 pin K is connected to
SumFLT_NC J6 pin M, and SumFLT_NO J6 pin L is open)
Example: <1/SFS?
>0001/SFS=0’cr’’lf’
N/A
SFS?
SFS=x
(See
Description of
Arguments)
Remote
Address
SPA=
4 bytes,
numeric
Command or Query.
Set Physical Address in the form xxxx, where:
xxxx = address between 0001 to 9999, resolution 0001
Example:
SPA=0412’cr’
SPA=
SPA?
SPA?
SPA=xxxx
(See
Description of
Arguments)
Set RTC
Time
TIM=
6 bytes,
numeric
Command or Query.
Sets or returns the RTC time in the form
hhmmss
, where:
hh = hours, between 00 and 23;
mm = minutes, between 00 and 59,
ss = seconds, between 00 and 59
Example:
(time = 23 hours, 12 minutes and 59 seconds since
midnight.):
<1/TIM=231259’cr’
>0001/TIM=’cr’’lf’
TIM =
TIM?
TIM*
TIM?
TIM=xxxxxx
(See
Description of
Arguments)
Содержание HPOD
Страница 10: ...MN HPOD IOM Revision 9 Table of Contents TOC viii MN HPOD IOM BLANK PAGE...
Страница 16: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Preface vi MN HPOD IOM Notes...
Страница 26: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Introduction 1 10 MN HPOD IOM BLANK PAGE...
Страница 27: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Introduction 1 11 MN HPOD IOM Notes...
Страница 37: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 External Connectors and Pinouts 2 10 MN HPOD IOM Notes...
Страница 50: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Updating Firmware 3 13 MN HPOD IOM BLANK PAGE...
Страница 51: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Updating Firmware 3 14 MN HPOD IOM Notes...
Страница 122: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Appendix A A 23 MN HPOD IOM BLANK PAGE...
Страница 138: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Appendix A A 39 MN HPOD IOM Notes...
Страница 139: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Appendix A A 40 MN HPOD IOM BLANK PAGE...
Страница 151: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Appendix B B 12 MN HPOD IOM Notes...
Страница 158: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Appendix C C 7 MN HPOD IOM BLANK PAGE...
Страница 159: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Appendix C C 8 MN HPOD IOM Notes...
Страница 160: ......
Страница 161: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...