HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier
Revision 9
Appendix B
B–9
MN/HPOD.IOM
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for
Command
or
Response
to Query
Description of Arguments
(Note that all arguments are ASCII numeric codes – i.e.,
ASCII codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to
query
(Target to
Controller)
Redundancy
State
N/A
1 byte,
value of 0,
1, 2
Query only.
Returns the current redundancy state in the form x, where:
0 = OFF
1 = 1:1 Redundancy
2 = 1:2 Redundancy
N/A
RED?
RED=x
(see
Description of
Arguments
for details)
Set switch
position
SSW=
1 byte,
value of 0,1
Command only.
For 1:1 systems only(sent to either unit):
Only used when system is in MANUAL redundancy mode
(RAM=0, both units).
Forces switch position in the form x, where:
1 = Forces switch to put SSPA 1 online
2 = Forces switch to put SSPA 2 online
SSW=
SSW?
N/A
N/A
Gain Offset
GOF=
5 bytes,
numerical
Command or Query.
Set or query the adjusted attenuation level, in 0.25 dB
increments, in a 1:1 redundancy system so power is equal
between the online and offline units when a switchover occurs,
in the form xx.xx.
Example:
GOF=02.00’cr’
GOF=
GOF?
GOF*
GOF?
GOF =xx.xx
(See
Description of
Arguments
for details)
Set Backup
Offset
SBO=
7 bytes,
numerical
Command or Query.
Set or query the adjusted attenuation level, in 0.25 dB
increments, in a 1:2 redundancy system so power is equal
between the online and offline units when a switchover occurs.
In the form #,xx.xx where:
# = 1 or 2
xx.xx = level, in 0.25 dB increments
Examples:
SBO=1,02.00’cr’ or SBO=2,02.50’cr’
SBO=
SBO?
SBO*
SBO?
SBO=#,xx.xx
(See
Description of
Arguments
for details)
Содержание HPOD
Страница 10: ...MN HPOD IOM Revision 9 Table of Contents TOC viii MN HPOD IOM BLANK PAGE...
Страница 16: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Preface vi MN HPOD IOM Notes...
Страница 26: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Introduction 1 10 MN HPOD IOM BLANK PAGE...
Страница 27: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Introduction 1 11 MN HPOD IOM Notes...
Страница 37: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 External Connectors and Pinouts 2 10 MN HPOD IOM Notes...
Страница 50: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Updating Firmware 3 13 MN HPOD IOM BLANK PAGE...
Страница 51: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Updating Firmware 3 14 MN HPOD IOM Notes...
Страница 122: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Appendix A A 23 MN HPOD IOM BLANK PAGE...
Страница 138: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Appendix A A 39 MN HPOD IOM Notes...
Страница 139: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Appendix A A 40 MN HPOD IOM BLANK PAGE...
Страница 151: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Appendix B B 12 MN HPOD IOM Notes...
Страница 158: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Appendix C C 7 MN HPOD IOM BLANK PAGE...
Страница 159: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Appendix C C 8 MN HPOD IOM Notes...
Страница 160: ......
Страница 161: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...