HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier
Revision 9
Serial-Based Remote Product Management
5–19
MN/HPOD.IOM
Parameter
Type
Command
(Instruction
& Qualifier)
Number of
Arguments
Description of Arguments
Response to
Command
Query
(Instruction &
Qualifier)
Response to
Query
Redundancy
State
RED=
1 byte,
value of 0,
1, 2
Command or Query.
Set or report as ON or OFF the redundancy state, in the form x,
where:
0 = Off
1 = 1:1 Redundancy
2 = 1:2 Redundancy
Example:
<1/RED=1’cr’
>0001/RED=’cr’’lf’
RED=
RED?
RED*
RED?
RED =x
Reference
Oscillator
Tuning
REF=
3 bytes,
numeric
Command or Query.
Adjusts the reference oscillator tuning voltage by sending a DAC
value in the form xxx, where:
xxx = numeric value from 0 to 255, and the default value is set to
87.
Example:
<1/REF=87’cr’
>0001/REF=
Note:
This command sets the DAC value, but the actual
Reference Oscillator tuning voltage can be monitored using the
RMS command.
REF=
REF?
REF*
REF?
REF=xxx
(See
Description of
Arguments)
Retrieve
Equipment
Type
N/A
22 bytes,
alphanumeri
c
Query only.
Returns the Model Number and the version of the MnC firmware
installed in the unit.
Example:
<1/RET?’cr’
>0001/RET=CPA-300 VER: 1.0.3’cr’’lf’
N/A
RET?
RET=x….x
(See
Description of
Arguments)
Содержание HPOD
Страница 10: ...MN HPOD IOM Revision 9 Table of Contents TOC viii MN HPOD IOM BLANK PAGE...
Страница 16: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Preface vi MN HPOD IOM Notes...
Страница 26: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Introduction 1 10 MN HPOD IOM BLANK PAGE...
Страница 27: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Introduction 1 11 MN HPOD IOM Notes...
Страница 37: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 External Connectors and Pinouts 2 10 MN HPOD IOM Notes...
Страница 50: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Updating Firmware 3 13 MN HPOD IOM BLANK PAGE...
Страница 51: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Updating Firmware 3 14 MN HPOD IOM Notes...
Страница 122: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Appendix A A 23 MN HPOD IOM BLANK PAGE...
Страница 138: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Appendix A A 39 MN HPOD IOM Notes...
Страница 139: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Appendix A A 40 MN HPOD IOM BLANK PAGE...
Страница 151: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Appendix B B 12 MN HPOD IOM Notes...
Страница 158: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Appendix C C 7 MN HPOD IOM BLANK PAGE...
Страница 159: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Appendix C C 8 MN HPOD IOM Notes...
Страница 160: ......
Страница 161: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...