Table 7–5 Power Problems
Symptom
Action
System does not
power on.
Check that AC power is available and all power cords
are plugged in.
Check the Power setting on the control panel. Toggle
the Power button to off, then back on to clear a remote
power disable.
Check error messages on the control panel.
Check that the ambient room temperature is within
environmental specifications (10–35°C, 50–95°F).
Internal power supply cables might not be plugged in at
the system board. Contact your service provider.
Power supply shuts
down after a few
seconds
The system may be powered off by one of the following:
—A remote management console command
—System software
—Fan failure
—Over-temperature condition
—Power supply failure
—Faulty CPU
Invoke RMC and use the env command for an
indication of a hardware problem. See Chapter 4 for
information on RMC.
Check that the power supplies are installed correctly
and correctly seated.
Содержание AlphaServer ES40
Страница 4: ......
Страница 11: ...xi 8 7 Regulatory Approvals 8 8 8 8 Acoustic Data 8 9 ...
Страница 12: ......
Страница 124: ......
Страница 128: ...5 4 ES40 Owner s Guide Figure 5 2 Enclosure Panel Removal Pedestal 1 2 PK0234 ...
Страница 131: ...Configuring and Installing Components 5 7 Figure 5 3 Removing Covers from a Tower PK0216 5 4 3 1 2 2 2 1 ...
Страница 132: ...5 8 ES40 Owner s Guide Figure 5 4 Removing Covers from a Pedestal Rack PK0215 1 4 5 3 2 1 2 ...
Страница 158: ...5 34 ES40 Owner s Guide Figure 5 17 PCI Card Installation Pedestal Rack View PK0245 2 3 1 ...
Страница 170: ......
Страница 212: ......
Страница 222: ......
Страница 228: ......