H-10
POST Error Messages
Writer: Pamela King Project: SMART-2DH Array Controller Reference Guide Comments: 295469-002
File Name: O-APPH.DOC Last Saved On: 2/27/98 12:10 PM
COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED
POST Error Messages
continued
1793
Slot x Drive Array - Array Accelerator Battery
Depleted. Data in Array Accelerator has been
lost. (Error message 1794 also displays.)
While the system was in use, power was
interrupted while data was in the Array
Accelerator memory. Power was not restored
within four days, and data in the Array
Accelerator was lost. Check all files for
potential data corruption.
-Or-
The Array Accelerator batteries have become
discharged while the system was off for an
extended period (Array Accelerator board Rev.
A or earlier).
-Or-
The controller was replaced with one that was
on the shelf for an extended period; batteries
are temporarily discharged (Array Accelerator
Rev. A or earlier).
1794
Slot x Drive Array - Array Accelerator Battery
Charge Low. Array Accelerator is temporarily
disabled. Array Accelerator will be reenabled
when battery reaches full charge.
The battery charge is below 90%. Posted
writes are disabled. When the batteries are
fully charged, the Array Accelerator will
automatically be reenabled and this POST
message will be discontinued. Replace the
Array Accelerator or the SMART-2DH Controller
if batteries do not recharge within 36 power-on
hours.
1795
Slot x Drive Array - SMART-2 Controller
Configuration Error. Data does not correspond
to this drive array. Array Accelerator is
temporarily disabled.
The data stored in the Array Accelerator does
not correspond to this drive array. Match the
Array Accelerator to the correct drive array.
-Or-
Run the Compaq System Configuration Utility
to clear data in the Array Accelerator.
1796
Slot x Drive Array - Array Accelerator is not
responding. Array Accelerator is temporarily
disabled.
The Array Accelerator is not responding.
Replace the Array Accelerator or the
SMART-2DH Controller.
continued