SMART-2DH Array Controller Reference Guide
Writer: Pamela King Project: SMART-2DH Array Controller Reference Guide Comments: 295469-002
File Name: J-APPC.DOC Last Saved On: 2/27/98 12:03 PM
COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED
Migrating to/from Other SMART
Array Controllers
The table below indicates what actions, if any, are required when migrating
from one array controller type to another within the SMART family of
controllers.
NOTE
: It is recommended that any time you move drive arrays or change
your configuration you should back up data.
Table C-1
Migrating to/from other Controllers
To
SMART-1
SMART-2/E
SMART-2/P
SMART-2SL
SMART-2DH
From
SMART-1
X
X
X
X
X
SMART-2/E
BU/Restore
X
X
X
X
SMART-2/P
BU/Restore
X
X
X
X
SMART-2SL
BU/Restore
FW Upgrade
FW Upgrade
X
X
SMART-2DH
BU/Restore
FW Upgrade
FW Upgrade
X
X
Legend:
X: No action required. Recommended back up of data prior to migrating to another controller.
BU/Restore: Mandatory data back up and restore to prevent data loss.
FW Upgrade: Upgrade of SMART-2/E or /P Controller FW to v1.90 or later is recommended to
allow connection of drive arrays to either SCSI bus. However, if a logical volume spans both
ports, the drives must be connected to the same port as they were with the original controller.
In all cases drives within a volume must keep their same relative order.