The SMART-2DH Controller produces diagnostic error messages at reboot.
Many of these Power-On Self-Test (POST) messages are self-explanatory and
suggest corrective actions for troubleshooting. Detailed information and
corrective actions are listed below.
NOTE
: SCSI port 1 refers to internal or external drives attached to the
internal port 1 connector. SCSI port 2 refers to external drives installed in a
Compaq ProLiant Storage System attached to the external port 2 connector.
Table H-1
POST Error Messages
Code
Meaning
Recommended Action
1702
SCSI Cable Error Detected. System Halted.
This message indicates a termination or cabling
problem with the system board integrated SCSI
controller. Refer to cabling diagrams in the
SMART-2DH Array Controller Installation Guide
for your system.
1720
Slot x Drive Array - S.M.A.R.T. Hard Drive
Detects Imminent Failure SCSI: Port y: SCSI
ID x.
The indicated drive has reported a S.M.A.R.T.
predictive-failure condition. It may fail at some
time in the future. If this drive is part of a non-
fault-tolerant configuration, back up all data
before replacing the drive and restore all data
afterwards. If this drive is part of a fault-
tolerant configuration, do not replace this drive
unless all other drives in the array are on-line.
Select
F1
key to resume.
1724
Slot x Drive Array - Physical Drive Position
Changes(s) Detected - Logical drive
configuration has automatically been
updated.
This message indicates that logical drive
configuration has been updated automatically
following physical drive position changes.
Select
F1
key to resume.