The DMI (Diagnostic Monitoring Interface) is developed for monitoring temperature, voltage,
current, transmitting power and receiving power for SFP (Mini-GBIC) ports. If the real detected
values, such as temperature, voltage, current etc., of the respective ports reach the threshold
of the connected transceiver, the system will shut down the device or send e-mail to notify the
related staff. The recipients can be specified via the SMTP configuration. Please refer to the
System Event Log—SMTP Configuration section.
Figure 67 – DMI interface
»
Port No.
: Select the pull-down menu to select a particular SFP port to display its information
and define reaction options.
»
Temperature
: The fields showing values measured in degrees Celsius. Select the radio button
labeled as
Off
to shut down the device or the other one labeled as
to send e-mail for
notifications when the port temperature reaches the threshold.
»
Voltage
: The fields showing values measured in voltages. Select the radio button labeled as
Off
to shut down the device or the other one labeled as
to send e-mail for notifications
when the port voltage reaches the threshold.
»
Current
: The fields showing values measured in milliamperes. Select the radio button
labeled as
Off
to shut down the device or the other one labeled as
to send e-mail for
notifications when the port current reaches the threshold.
»
TX PWR
: The fields showing values measured in milliwatts. Select the radio button labeled as
Off
to shut down the device or the other one labeled as
to send e-mail for notifications
when the port transmitting power reaches the threshold.
»
RX PWR
: The fields showing values measured in milliwatts. Select the radio button labeled as
Off
to shut down the device or the other one labeled as
to send e-mail for notifications
when the port receiving power reaches the threshold.