Chapter 6
Verifying the OneCell installation
OneCell
®
Installation and Commissioning, RP5000 series, Release 4.0
6-7
D
R
A
F
T
Figure 6-5.
Service Status
Table 6-3. Service Status
Parameter
Description
MME Connection
•
YES – The Baseband Controller has S1AP connection with the
MME.
•
NO – The Baseband Controller does not have S1AP connection
with the MME.
Configuration from HeMS
•
YES – The Baseband Controller has received the required
configuration from HeMS
•
NO – The Baseband Controller has not received the configuration
from HeMS.
Number of IPSec Tunnels
None - tunnel mode is Non IPSec
One - tunnel mode is Single IPSec Tunnel
Two - tunnel mode is Dual IPSec Tunnel
IPSec Connection Status
YES - A secure connection is established with the Security Gateway
NO - No secure connection exists with the Security Gateway
NON IPSec - The connection does not use IPSec.
Dual Ipsec - The connection uses both OAM and S1 IPSec
connections.
IPSec Tunnel (per Tunnel 1, Tunnel 2 or Non IPSec)
IPSec Connection Status
•
ENABLED – Tunnel is established and connected
•
DISABLED – Tunnel is not established
•
ERROR – Error occurred during tunnel establishment
Security Gateway Address
IP Address of the Security Gateway through which the tunnel is
established
Tunnel Internal Address
Tunnel IP address provided by the Security Gateway after successful
session establishment.
<A.B.C.D>
Содержание OneCell RP5100i
Страница 7: ...Contents OneCell Installation and Commissioning RP5000 series Release 4 0 vii DRAFT ...
Страница 10: ...List of tables x 913035 4 0 04 June 2019 DRAFT ...
Страница 12: ...Document revision history xii 913035 4 0 04 June 2019 DRAFT ...
Страница 18: ...About this document xviii 913035 4 0 04 June 2019 DRAFT ...
Страница 20: ...DRAFT ...
Страница 28: ...DRAFT ...
Страница 42: ...Chapter 4 RP5100i installation 4 6 913035 4 0 04 June 2019 DRAFT 5 Replace the ceiling tile with the cutouts ...
Страница 68: ...Chapter 4 RP5100i installation 4 32 913035 4 0 04 June 2019 DRAFT Installation is complete ...
Страница 69: ...DRAFT Part III Commissioning Chapter 5 Configuring the OneCell system ...
Страница 70: ...DRAFT ...