Chapter 6
Verifying the OneCell installation
OneCell
®
Installation and Commissioning, RP5000 series, Release 4.0
6-5
D
R
A
F
T
Timing Source Status
This section displays the Timing source of the Baseband Controller, either GPS or
PTP (1588).
View the Timing Source Status for GPS and ensure that Timing Good and Got Fix are
Green.
Figure 6-3.
Timing Source Status - GPS
Link to GPS details page
View the Timing Source Status for GPS and ensure that the PTP Server InUse IP
address and Timing Cluster ID field have data.
Up Time
The amount of time the OneCell has been up.
HH:MM:SS
Number of Sectors
Number of sectors configured on the device
Supported values:
•
1
•
2
Admin Status of each Sector
•
UP – The OneCell Sector is providing service. (Example: at least
one Radio Point has RftxStatus of 'ON')
•
DOWN – The OneCell Sector is not providing service.
Operational Status of each
Sector
Supported values:
•
TRUE
•
FALSE
Table 6-2. Device Information parameters (continued)
Parameter
Description
Содержание OneCell RP5100i
Страница 7: ...Contents OneCell Installation and Commissioning RP5000 series Release 4 0 vii DRAFT ...
Страница 10: ...List of tables x 913035 4 0 04 June 2019 DRAFT ...
Страница 12: ...Document revision history xii 913035 4 0 04 June 2019 DRAFT ...
Страница 18: ...About this document xviii 913035 4 0 04 June 2019 DRAFT ...
Страница 20: ...DRAFT ...
Страница 28: ...DRAFT ...
Страница 42: ...Chapter 4 RP5100i installation 4 6 913035 4 0 04 June 2019 DRAFT 5 Replace the ceiling tile with the cutouts ...
Страница 68: ...Chapter 4 RP5100i installation 4 32 913035 4 0 04 June 2019 DRAFT Installation is complete ...
Страница 69: ...DRAFT Part III Commissioning Chapter 5 Configuring the OneCell system ...
Страница 70: ...DRAFT ...