CommScope OneCell RP5100i Скачать руководство пользователя страница 1

Hardware Installation and 
Commissioning, RP5000 series

Release 4.0

Document Number:

 

913035

 

OneCell

®

Document Revision:

 

4.0.04 

Date:

 

June

 

2019

Содержание OneCell RP5100i

Страница 1: ...Hardware Installation and Commissioning RP5000 series Release 4 0 Document Number 913035 OneCell Document Revision 4 0 04 Date June 2019 ...

Страница 2: ...TS INFORMATION AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT ARE PRESENTED WITHOUT WARRANTY OF ANY KIND EXPRESS OR IMPLIED USERS MUST TAKE FULL RESPONSIBILITY FOR THEIR APPLICATION OF ANY PRODUCTS THE SOFTWARE LICENSE AND LIMITED WARRANTY FOR THE ACCOMPANYING PRODUCT ARE SET FORTH IN THE INFORMATION PACKET THAT SHIPPED WITH THE PRODUCT AND ARE INCORPORATED HEREIN BY REFERENCE ...

Страница 3: ...erview 1 2 CommScope OneCell system 1 2 OneCell hardware components 1 3 Baseband Controller physical ports 1 3 Chapter 2 Preparing to install the OneCell system Overview 2 2 Before installing the OneCell components 2 2 PART 2 ONECELL COMPONENT INSTALLATION Chapter 3 Baseband Controller installation Preparing for Baseband Controller installation 3 2 Installing the Baseband Controller into a rack 3 ...

Страница 4: ...iguration 5 6 Accessing the Web GUI 5 13 Configuring the Baseband Controller 5 16 Uploading XML configuration file 5 16 Configuring the Baseband Controller manually 5 25 Configuring firewall ports 5 27 Chapter 6 Verifying the OneCell installation Overview 6 2 Verify the OneCell system installation 6 2 Verify the Baseband Controller installation 6 3 Device Information 6 4 Timing Source Status 6 5 R...

Страница 5: ...erns B 4 Appendix C Specifications Electrical ratings and technical data C 2 SPF SPF specifications C 2 Appendix D Field Replaceable Units FRU overview D 2 Replacing Baseband Controller modules D 2 Prerequisites D 2 Off site activities D 3 On site activities D 7 Post Install Verification D 11 Replacing Radio Points D 13 Prerequisites D 13 On site activities D 14 Replacing a ceiling RP5100i above t...

Страница 6: ...n guidelines Overview E 2 Cable handling E 2 Cable termination E 3 Cable splicing E 4 Cable termination E 5 Cable grounding E 10 Lightning protection E 12 Important guidelines E 12 Indoor box E 12 Outdoor protection E 13 Ceiling connector E 15 Patch panel E 17 Power separation guidelines E 17 ...

Страница 7: ...Contents OneCell Installation and Commissioning RP5000 series Release 4 0 vii DRAFT ...

Страница 8: ...Baseband single Controller deployment 5 3 Figure 6 1 Baseband Controller front panel 6 2 Figure 6 2 Management Mode Dashboard 6 4 Figure 6 3 Timing Source Status GPS 6 5 Figure 6 4 Timing Source Status PTP 6 6 Figure 6 5 Service Status 6 7 Figure 6 6 Alarms 6 8 Figure E 1 Unreel cable E 2 Figure E 2 Cable with sock attached using tie wrap E 3 Figure E 3 RJ45 IP67 connector E 3 Figure E 4 Assemblin...

Страница 9: ...on file 5 17 Table 5 3 Deployment Wizard steps 5 26 Table 5 4 Configurable DMS service and protocol ports 5 27 Table 6 1 OneCell Baseband Controller operational status 6 3 Table 6 2 Device Information parameters 6 4 Table 6 3 Service Status 6 7 Table 6 4 CORE LED local network connectivity issues 6 9 Table 6 5 CORE LED states 6 9 Table 6 6 STATUS LED core network connectivity issues 6 10 Table A 1...

Страница 10: ...List of tables x 913035 4 0 04 June 2019 DRAFT ...

Страница 11: ...d Controller physical ports on page 1 3 including Table 1 1 on page 1 4 Chapter 5 Configuring the OneCell system Revised Timing Source Boundary Clock Interface Port in Table 5 2 on page 5 17 Added GPS Information bullet to Configuring the Baseband Controller manually on page 5 25 Revised Whitelist Configuration in Table 5 3 on page 5 26 Chapter 6 Verifying the OneCell installation Revised Verify t...

Страница 12: ...Document revision history xii 913035 4 0 04 June 2019 DRAFT ...

Страница 13: ... network architects and business planners who are responsible for the planning and design of the CommScope OneCell deployment environment Purpose This guide provides the information necessary for installing the OneCell hardware in the operator s network What you need to know The reader should have a basic understanding of Data networks LTE technology General telecommunications practices Customer d...

Страница 14: ...OneCell Devices 913158 Describes Device Management Portal features by menu items used by technical support personnel DMS Administration and Utilities Reference for OneCell Devices 913155 Describes how to operate administer and maintain the DMS device server for OneCell devices Troubleshooting the DMS Network 913161 Describes how to maintain the DMS and identify verify and resolve problems in the d...

Страница 15: ...913022 Covers common troubleshooting scenarios in deployed devices and troubleshooting methods OneCell Deployment Guide 913028 Contains the device network overview including CommScope provided components and required components from other vendors DMS overview and device overview and requirements OM and KPI Reference for OneCell Devices 913159 Describes the operational measurements and key performa...

Страница 16: ...ont Indicates system output in a command line or system generated file For example IP address 192 23 10 12 is alive Italic output font Indicates a variable in system output in a command line or system generated file For example Installation of release release is complete Plain italic font Indicates file names directory paths book titles chapter titles and user accounts Bold font Indicates text tha...

Страница 17: ...ii DRAFT Notes cautions and warnings NOTE Notes provide additional information about the subject text CAUTION Cautions indicate that procedures if performed incorrectly can cause equipment damage or data loss WARNING Warnings indicate that procedures if performed incorrectly can harm you ...

Страница 18: ...About this document xviii 913035 4 0 04 June 2019 DRAFT ...

Страница 19: ...DRAFT Part I Overview and preparation Chapter 1 CommScope OneCell overview Chapter 2 Preparing to install the OneCell system ...

Страница 20: ...DRAFT ...

Страница 21: ...ease 4 0 1 1 DRAFT Chapter 1 CommScope OneCell overview This chapter contains a high level overview of the OneCell deployment and the OneCell components installed in the OneCell system Overview 1 2 CommScope OneCell system 1 2 OneCell hardware components 1 3 ...

Страница 22: ...exibility to neutralize macro interference in co channel small cell deployments It can be used to deliver unprecedented levels of capacity to hot spot areas by deploying radio points with overlapping coverage and enabling multi user MIMO In addition to these important benefits in user experience and data capacity OneCell provides superior economics and investment protection ease of deployment supp...

Страница 23: ...lowing components Baseband Controller Baseband Controller Chassis Baseband Controller Module Power Fan Unit PFU Baseband Controller physical ports The following ports are on the front panel of the Baseband Controller Module Table 1 1 shows the port assignments In addition there is a connector used for the GPS antenna cable NOTE For more detailed BC port information see OneCell Network Planning Gui...

Страница 24: ... SFP port 8 Back haul dual media RJ45 SFP data port 9 Dual media RJ45 SFP port for front haul RP management RP timing IEEE1588 Redundancy High Availability 10 Dual media port provides 1588 timing SOAP XML to Radio Point RP units Either this copper port or fiber port 10 SFP not provided is used to provide 1588 timing to RPs 11 10G SFP fiber port for front haul IQ data 12 Not used Copper wire ports ...

Страница 25: ...ssioning RP5000 series Release 4 0 2 1 DRAFT Chapter 2 Preparing to install the OneCell system This section has the steps to complete before starting the OneCell installation Overview 2 2 Before installing the OneCell components 2 2 ...

Страница 26: ...ter 5 Ruggedized Radio Point Installation Before installing the OneCell components Before installing the OneCell components the system integrator must plan the network for the topology that will be deployed See OneCell Network Planning Guide 913023 CommScope recommends that cables and switches be in place before installing the OneCell components See Appendix E Cable installation and power separati...

Страница 27: ...DRAFT Part II OneCell component installation Chapter 3 Baseband Controller installation Chapter 4 RP5100i installation ...

Страница 28: ...DRAFT ...

Страница 29: ...s the Baseband Controller installation procedures including chassis installation into a rack Baseband Controller Module and Power Fan Unit installation into the Baseband Controller Chassis and the cables required for a basic installation Preparing for Baseband Controller installation 3 2 Installing the Baseband Controller into a rack 3 2 ...

Страница 30: ...h room for the Baseband Controller in the rack Installing the Baseband Controller into a rack The Baseband Controller can be installed in a 19 inch or 600mm rack The Baseband Controller Chassis package contains two kits one with 19 inch brackets and one with 600mm brackets CAUTION The Baseband Controller when mounted must be in the horizontal position No other orientations are allowed NOTE The cha...

Страница 31: ...ler installation OneCell Installation and Commissioning RP5000 series Release 4 0 3 3 DRAFT 2 Slide the chassis into the rack 3 Line up the holes in the chassis ears to the holes in the rack 4 Secure the chassis with the screws ...

Страница 32: ...Chapter 3 Baseband Controller installation 3 4 913035 4 0 04 June 2019 DRAFT 5 Carefully slide the BC into the front of the chassis 6 Secure the BC by tightening the front panel screws ...

Страница 33: ...DRAFT 7 In the back of the rack carefully slide the PFU into the back of the chassis CAUTION The PFU has a fan hazard A label is affixed to the top of the PFU indicating the hazard Fan hazard label NOTE The connectors on the PFU should fit easily into the connector on the BC Do not force the PFU into the chassis ...

Страница 34: ...Chapter 3 Baseband Controller installation 3 6 913035 4 0 04 June 2019 DRAFT 8 Secure the PFU by tightening the thumb screws 9 Connect the power cord to the PFU ...

Страница 35: ...tallation OneCell Installation and Commissioning RP5000 series Release 4 0 3 7 DRAFT 10 On the Baseband Controller Module s front panel connect the GPS antenna cable 11 Connect the Ethernet or fiber optic cable to the appropriate port ...

Страница 36: ...9 DRAFT 12 On the back of the Baseband Controller turn on the power The LEDs on the front panel will be solid green when the power is on If none are on check your power connection If the LED pattern is other than all green see Baseband Controller LED patterns on page B 2 ...

Страница 37: ...e 4 0 4 1 DRAFT Chapter 4 RP5100i installation This chapter describes installing indoor Radio Points on ceiling tiles above ceiling tiles on poles and in a flown configuration RP5100i installation overview 4 2 Ceiling mount 4 2 Flown mount 4 20 Pole mount 4 28 ...

Страница 38: ...e mount NOTE Once the Radio Point is installed and powered on it may take up to 20 minutes for the frequency to stabilize and lock Ceiling mount Mounting the Radio Point RP above or on the ceiling tile requires the following hardware provided by CommScope Radio Point plate and screws 4 octagon box 1 1 2 deep with 1 2 side cutouts Clamp and screw Figure 4 1 CommScope ceiling mount kit contents Octa...

Страница 39: ...ommissioning RP5000 series Release 4 0 4 3 DRAFT Mounting the Radio Point RP above or on the ceiling tile requires the following hardware provided by the system integrator Drop rail Eaton B line BA50 recommended Figure 4 2 Drop rail system integrator provided ...

Страница 40: ...the ceiling tile 1 Remove two ceiling tiles from the overhead 2 Place the octagon box on the tile and trace the outline Cut the opening 3 Drill a 1 2 inch diameter hole for the Ethernet cable pass through NOTE Use a 1 1 2 deep RACO 8125 or equivalent Hole for mounting plate 1 inch diameter hole ...

Страница 41: ... RP5100i installation OneCell Installation and Commissioning RP5000 series Release 4 0 4 5 DRAFT 4 Attach the octagon box to the ceiling bracket using a clamp and screw Octagon box Screw Drop ceiling rail Clamp ...

Страница 42: ...Chapter 4 RP5100i installation 4 6 913035 4 0 04 June 2019 DRAFT 5 Replace the ceiling tile with the cutouts ...

Страница 43: ...Chapter 4 RP5100i installation OneCell Installation and Commissioning RP5000 series Release 4 0 4 7 DRAFT 6 Install the drop rail octagon box assembly over the modified tile ...

Страница 44: ...0 04 June 2019 DRAFT 7 Attach the mounting plate onto the octagon box and feed the Ethernet cable through the small hole in the ceiling tile 8 Attach base plate to the Radio Point NOTE Apply thread locking compound to screws prior to installation ...

Страница 45: ...Chapter 4 RP5100i installation OneCell Installation and Commissioning RP5000 series Release 4 0 4 9 DRAFT 9 Mount the Radio Point on the octagon box plate ...

Страница 46: ...Chapter 4 RP5100i installation 4 10 913035 4 0 04 June 2019 DRAFT 10 Secure Radio Point to plate 11 Connect Ethernet cables to the Radio Point ...

Страница 47: ...Chapter 4 RP5100i installation OneCell Installation and Commissioning RP5000 series Release 4 0 4 11 DRAFT 12 Attach the plastic cover to the Radio Point ...

Страница 48: ...Chapter 4 RP5100i installation 4 12 913035 4 0 04 June 2019 DRAFT 13 Replace the ceiling tile next to the Radio Point ...

Страница 49: ...Chapter 4 RP5100i installation OneCell Installation and Commissioning RP5000 series Release 4 0 4 13 DRAFT Mounting the Radio Point above the ceiling tile 1 Remove ceiling tile from the overhead ...

Страница 50: ...apter 4 RP5100i installation 4 14 913035 4 0 04 June 2019 DRAFT 2 Attach the octagon box to the bracket NOTE CommScope recommends an Eaton B line BA50A adjustable bracket Clamp Drop rail Octagon box Screw ...

Страница 51: ...Cell Installation and Commissioning RP5000 series Release 4 0 4 15 DRAFT 3 Attach the bracket to the mounting plate to the octagon box 4 Attach plate to the Radio Point NOTE Apply thread locking compound to screws prior to installation ...

Страница 52: ...Chapter 4 RP5100i installation 4 16 913035 4 0 04 June 2019 DRAFT 5 Attach the Radio Point to the octagon box mounting plate ...

Страница 53: ...Chapter 4 RP5100i installation OneCell Installation and Commissioning RP5000 series Release 4 0 4 17 DRAFT 6 Install drop rail above the ceiling tile ...

Страница 54: ...Chapter 4 RP5100i installation 4 18 913035 4 0 04 June 2019 DRAFT 7 Connect the Ethernet cables to the Radio Point ...

Страница 55: ...ter 4 RP5100i installation OneCell Installation and Commissioning RP5000 series Release 4 0 4 19 DRAFT 8 Attach the cover to the Radio Point NOTE The minimum clearance for cooling is 3 inches Ceiling tile 3 ...

Страница 56: ...guration is used for building where there are no drop ceilings Mounting the Radio Point RP in the flown configuration requires the following hardware provided by CommScope in the mounting kit Radio Point plate and screws 4 octagon box 1 1 2 deep with 1 2 side cutouts NOTE Remove the top middle cutout Clamp and screw this hardware is not required for the flown mount option ...

Страница 57: ...ommScope flown mount kit contents Octagon box Clamp with 1 screw Mounting plate for octagon box with 2 screws Mounting plate for RP with 4 screws Mounting the Radio Point RP in the flown configuration requires the following hardware provided by the system integrator Rod 3 8 inch threaded Nut Lock nut nylon Flat washers ...

Страница 58: ...h rod cut to the required length to the ceiling 2 Install the nut and a flat washer on the rod 3 Slide the octagon box on the rod and install a flat washer and the nylon lock nut NOTE Be sure the bracket is tight between the nuts and there is enough clearance at the end of the rod to attach the bracket to the Radio Point ...

Страница 59: ...Chapter 4 RP5100i installation OneCell Installation and Commissioning RP5000 series Release 4 0 4 23 DRAFT 4 Attach plate to octagon box ...

Страница 60: ...Chapter 4 RP5100i installation 4 24 913035 4 0 04 June 2019 DRAFT 5 Attach the mounting plate to the Radio Point 6 Attach the Radio Point to the octagon box ...

Страница 61: ...Chapter 4 RP5100i installation OneCell Installation and Commissioning RP5000 series Release 4 0 4 25 DRAFT 7 Connect the Ethernet cable to the Radio Point ...

Страница 62: ...Chapter 4 RP5100i installation 4 26 913035 4 0 04 June 2019 DRAFT 8 Attach the plastic cover to the Radio Point ...

Страница 63: ...Chapter 4 RP5100i installation OneCell Installation and Commissioning RP5000 series Release 4 0 4 27 DRAFT Installation is complete ...

Страница 64: ...o Point RP on a pole requires the following hardware provided by CommScope in the mounting kit Mounting bracket Screws Figure 4 4 Mounting bracket kit contents Mounting the Radio Point RP on a pole requires the following hardware provided by the system integrator Adjustable clamp at least 2 inches larger than the circumference of the pole Pole mount installation 1 Attach the bracket to the Radio p...

Страница 65: ...Installation and Commissioning RP5000 series Release 4 0 4 29 DRAFT 2 Slide the adjustable clamp through the slots on the Radio Point bracket 3 Wrap the clamp around the pole and tighten the clamp screw to secure the Radio Point to the pole ...

Страница 66: ...Chapter 4 RP5100i installation 4 30 913035 4 0 04 June 2019 DRAFT 4 Connect the Ethernet cable to the Radio Point ...

Страница 67: ...Chapter 4 RP5100i installation OneCell Installation and Commissioning RP5000 series Release 4 0 4 31 DRAFT 5 Attach the plastic cover to the Radio Point ...

Страница 68: ...Chapter 4 RP5100i installation 4 32 913035 4 0 04 June 2019 DRAFT Installation is complete ...

Страница 69: ...DRAFT Part III Commissioning Chapter 5 Configuring the OneCell system ...

Страница 70: ...DRAFT ...

Страница 71: ...ries Release 4 0 5 1 DRAFT Chapter 5 Configuring the OneCell system Overview 5 2 Configuring Ethernet switches 5 3 Configuring aggregate switches 5 6 Accessing the Web GUI 5 13 Configuring the Baseband Controller 5 16 Configuring firewall ports 5 27 ...

Страница 72: ... the Installation mode see OneCell Administration 913026 In preparation of configuring the OneCell system Use the Controller GUI called the Web GUI to configure all components except the Ethernet switches Confirm with the operator that the Baseband Controller is provisioned and configured on the DMS Configuring the Baseband Controller using the Web GUI completes the Baseband Configuration Once the...

Страница 73: ... OneCell Installation and Commissioning RP5000 series Release 4 0 5 3 DRAFT Configuring Ethernet switches Figure 5 1 shows an example of a single OneCell Baseband Controller deployment Figure 5 1 OneCell Baseband single Controller deployment ...

Страница 74: ...C port 0 Untagged IPSec S1 7 BC MGT Untagged Management 8 CU1 RP1 Tagged Untagged IQ 1588 9 CU1 RP2 Tagged Untagged IQ 1588 10 Add RP as required Tagged Untagged IQ 1588 11 Add RP as required Tagged Untagged IQ 1588 12 Add RP as required Tagged Untagged IQ 1588 13 Add RP as required Tagged Untagged IQ 1588 14 Add RP as required Tagged Untagged IQ 1588 15 Add RP as required Tagged Untagged IQ 1588 ...

Страница 75: ...rmation to forward traffic to interfaces who s clients want to receive the traffic In the absence of a multicast router in a network an IGMP querier is configured to solicit requests from hosts that want to receive IP multicast traffic 19 Add RP as required Tagged Untagged IQ 1588 20 Add RP as required Tagged Untagged IQ 1588 21 Add RP as required Tagged Untagged IQ 1588 22 Add RP as required Tagg...

Страница 76: ...ier at the global prompt switch config ip igmp snooping querier 3 Disable IGMP snooping on Management IPsec S1 and 1588 only interfaces Syntax no ip igmp snooping vlan vlan id Example switch config no ip igmp snooping vlan 399 switch config no ip igmp snooping vlan 211 4 Enable jumbo frames on IQ vlan interfaces switch config system mtu jumbo 9198 5 Configure port channel load balancing switch con...

Страница 77: ...gmp snooping vlan 280 no ip igmp snooping vlan 230 mls qos crypto pki trustpoint TP self signed 446807296 enrollment selfsigned subject name cn IOS Self Signed Certificate 446807296 revocation check none rsakeypair TP self signed 446807296 crypto pki certificate chain TP self signed 446807296 certificate self signed 01 30820229 30820192 A0030201 02020101 300D0609 2A864886 F70D0101 05050030 30312E3...

Страница 78: ...F 0603551D 23041830 168014BF 453BCF1D 307BAEB2 C298DA6F AAA57473 BEEC6F30 1D060355 1D0E0416 0414BF45 3BCF1D30 7BAEB2C2 98DA6FAA A57473BE EC6F300D 06092A86 4886F70D 01010505 00038181 006C74E7 7363409C 0A8C4A07 E7F56282 14691620 26F25580 7BD60850 971C5DB6 DA1A3845 8E63C19B 2ACC9180 0142A792 E0A09061 76D27A78 D867782F F9B4107E 91C8644C E7736783 29B69A0D 66AB1BC0 5FA34417 35259C74 96806102 8572EEE7 95...

Страница 79: ...switchport trunk allowed vlan 10 211 switchport mode trunk mls qos trust dscp service policy input 1588 interface GigabitEthernet1 0 2 switchport trunk native vlan 211 switchport trunk allowed vlan 10 211 switchport mode trunk mls qos trust dscp service policy input 1588 interface GigabitEthernet1 0 3 switchport trunk native vlan 211 switchport trunk allowed vlan 10 211 switchport mode trunk mls q...

Страница 80: ... 211 switchport trunk allowed vlan 10 211 switchport mode trunk mls qos trust dscp service policy input 1588 interface GigabitEthernet1 0 8 switchport trunk native vlan 211 switchport trunk allowed vlan 10 211 switchport mode trunk mls qos trust dscp service policy input 1588 interface GigabitEthernet1 0 9 switchport trunk native vlan 211 switchport trunk allowed vlan 10 211 switchport mode trunk ...

Страница 81: ... trunk interface GigabitEthernet1 0 15 description setup CU 48 1588 interface switchport access vlan 211 switchport mode access mls qos trust dscp service policy input 1588 no ip igmp snooping tcn flood interface GigabitEthernet1 0 16 description CU eth1 IQ switchport access vlan 10 switchport mode access channel protocol lacp channel group 1 mode passive interface GigabitEthernet1 0 17 descriptio...

Страница 82: ...l group 2 mode active interface GigabitEthernet1 0 22 description IQ uplink out for 2 switch switchport access vlan 10 switchport mode access channel protocol lacp channel group 2 mode active interface GigabitEthernet1 0 23 switchport access vlan 211 switchport mode access mls qos trust dscp service policy input 1588 interface GigabitEthernet1 0 24 description UPlink SIQ core switchport trunk allo...

Страница 83: ...244 line vty 0 4 password 7 0820455C1F180B16 login line vty 5 15 password 7 0820455C1F180B16 login end Accessing the Web GUI The controller GUI is accessible over secure http The application for the GUI listens on port 6002 Use the controller GUI to configure components after initial hardware installation view status and statistics of the controller and its associated Radio Points The following br...

Страница 84: ...erating System 1 Connect a laptop to the MGMT port on the Baseband Controller 2 Assign a Static IP address to the laptop Configure the following network settings IP address 192 168 8 20 Subnet mask 255 255 255 0 Gateway 192 168 8 1 3 Open a supported browser 4 Enter URL https 192 168 8 1 6002 5 Sign in to the Web GUI User ID admin Password admin1234 ...

Страница 85: ...Chapter 5 Configuring the OneCell system OneCell Installation and Commissioning RP5000 series Release 4 0 5 15 DRAFT The Installation mode page displays ...

Страница 86: ...e manually skip to Configuring the Baseband Controller manually Uploading XML configuration file 1 Create a tar or tar gz or zip file containing onecell config xml file Operator provided Contains all the operator parameters such as HeMS and Security Gateway URL information and the IP addresses for all of the Baseband Controller interfaces Operator Root Certificate Licenses bin file Optional Radio ...

Страница 87: ...nel2 Dual IPSec Mode nonIPSec Non IPSec Mode CA Traffic Mode Tunnel Mode for EPC Communication ipsecTunnel1 Single IPSec Mode ipsecTunnel2 Dual IPSec Mode nonIPSec Non IPSec Mode noCA No CA Mode Timing Source GPS Timing Source is GPS Boundary Clock Interface Port boundaryClock Timing Source is PTP with a dedicated Boundary Clock port configured backHaul Timing Source is PTP with no dedicated Bound...

Страница 88: ...Client mode The DHCP client fetches IP addresses from the DHCP server and assigns them to the interface User configuration is not required IP Address IP Address of the interface A B C D Subnet Mask or CIDR Classless Inter Domain Routing Network subnet mask of the client CIDR format 1 32 Default Gateway The IP Address of the router on this subnet A B C D Primary DNS Address IP Address of the Primar...

Страница 89: ...ress of the Secondary DNS Server A B C D Note This field is optional if the Primary DNS Address is configured VLAN ID Access Mode range 0 Trunk Mode range 11 to 4095 MTU Range 64 to 1998 Network Interface Port Configurations Boundary Clock Configuration IP Address Assignment Static mode IP Addresses are configured manually DHCP Client mode The DHCP client will fetch IP addresses from the DHCP serv...

Страница 90: ...d the Cluster Multicast IP Address used in pacemaker Range 1 to 254 Network Interface Port Configurations Redundancy IP Address Assignment Static mode IP Addresses are configured manually DHCP Client mode The DHCP client fetches IP addresses from the DHCP server and assigns them to the interface User configuration is not required IP Address IP Address of the interface A B C D Subnet Mask or CIDR C...

Страница 91: ...sing Tunnel Inner Address Tunnel IP Address provided by the Security Gateway after successful session establishment A B C D Tunnel CIDR CIDR format 1 32 Tunnel Internal DNS IP Address A B C D Exclude Configuration Payload CP True Configuration Payload is excluded during IKE processing False Configuration Payload is included during IKE processing Operator Configuration Security Gateway 2 Configurat...

Страница 92: ...nfiguration CA Server URL The URL value to be used in the HTTP Post Request Header to the CA Server CA Server Identity Operator CA server name or ID of the CMP Server or sub CMS CA server SA Certificate Identifier Unique Identifier located in the certificate issued by the Certificate Authority CA It is used for Subject Alt Name of the certificate Contains the Baseband Controller s MAC address stri...

Страница 93: ... greater values of a Type INTEGER 0 215 1 Uncertainty Altitude Uncertainty altitude h expressed in meters is derived from the Uncertainty Altitude k by h 45 x 1 025k 1 Type INTEGER 0 127 Position Estimate Uncertainty Semi Major Uncertainty r is derived from the uncertainty code k by r 10 x 1 1k 1 Type INTEGER 0 127 Uncertainty Semi Minor Uncertainty r is derived from the uncertainty code k by r 10...

Страница 94: ...values CBC DES None default Private Key User defined string SNMP Enabled Alarms List of SNMP Trap Names that can be enabled or disabled for trap generation from the OneCell device Whitelist Configuration Whitelist Provides Radio Point MAC Addresses for Whitelist in line in the config xml When in line Whitelist is provided the Whitelist file will not be considered for upload Whitelist File Name of ...

Страница 95: ...pplicable to this deployment or has not yet been configured Green Configuration has been successfully validated Red Errors have been encountered that must be corrected If the XML file fails validation click the hyperlink to locate the errors Configuring the Baseband Controller manually If you choose to enter the configuration manually use one of the following methods to advance to the next step Se...

Страница 96: ...k interface items Management Port Backhaul Boundary Clock If timing source is from a PTP server Fronthaul High Availability 4 Operator Network Access configuration Operator Network Access configuration contains sub menus for configuring the following operator access items HeMS Security PTP Server CA Server Root Certificate 5 Nominal GPS Configuration This screen contains configuration for Nominal ...

Страница 97: ...able 5 3 Deployment Wizard steps continued Step Menu Name Description Table 5 4 Configurable DMS service and protocol ports Row Service TCP UDP Protocol port Protocol Configurable Use 1 HDM Admin console TCP 9002 HTTP Install Upgrade only HDM Admin console HDM Managed console TCP 7003 HTTP Install Upgrade only HDM Managed console 2 Load Balancer TCP Configured port HTTP Load Balancer setup only Lo...

Страница 98: ...tion TCP 7003 HTTP Install Upgrade only Device to DMS 8 XML DB access TCP Configured port FTP Install Upgrade only XML DB access To copy ODF Factory files into Database for import Table 5 4 Configurable DMS service and protocol ports continued Row Service TCP UDP Protocol port Protocol Configurable Use ...

Страница 99: ...6 1 DRAFT Chapter 6 Verifying the OneCell installation Overview 6 2 Verify the OneCell system installation 6 2 Verify the Baseband Controller installation 6 3 Verify local network connectivity 6 9 Verify local network connectivity 6 9 Verify OneCell RF coverage 6 10 ...

Страница 100: ...used to verify the OneCell installation are Baseband Controller and Radio Point LEDs Baseband Controller Web GUI Ping tests User Equipment UE logs Verify the OneCell system installation To verify that the OneCell system installation is operating check the Baseband Controller LEDs The STATUS TIMING and CORE LEDs should be solid green For more information on troubleshooting the OneCell system instal...

Страница 101: ...m DMS Yes Remotes connected Yes Connection to MME Yes Sectors UP Yes Chapter 6 Verifying the OneCell installation OneCell Installation and Commissioning RP5000 series Release 4 0 6 3 DRAFT Verify the Baseband Controller installation Once the BC reboot is complete log into the WebGUI to display the Management Mode Dashboard Check the following information on the Dashboard Device Information Timing ...

Страница 102: ...lays the status of the overall OneCell device components at a glance You can view the current status of the Baseband Controller Verify that Device Status Admin Status and Operational Status are all green Table 6 2 Device Information parameters Parameter Description Device Status The current operational status of the device Supported values Up Initializing Error Disabled ...

Страница 103: ...age View the Timing Source Status for GPS and ensure that the PTP Server InUse IP address and Timing Cluster ID field have data Up Time The amount of time the OneCell has been up HH MM SS Number of Sectors Number of sectors configured on the device Supported values 1 2 Admin Status of each Sector UP The OneCell Sector is providing service Example at least one Radio Point has RftxStatus of ON DOWN ...

Страница 104: ...of RPs In Service If not navigation to the Radio Point Information page For more information on the Radio Point Information page see OneCell Administration 913026 NOTE Click the Link icon in the upper right corner of this area to navigate to the Radio Point Information page Service Status Verify the status of the following MME Connection Configuration from HeMS IPsec Connection Status IPSec Tunnel...

Страница 105: ...n IPSec One tunnel mode is Single IPSec Tunnel Two tunnel mode is Dual IPSec Tunnel IPSec Connection Status YES A secure connection is established with the Security Gateway NO No secure connection exists with the Security Gateway NON IPSec The connection does not use IPSec Dual Ipsec The connection uses both OAM and S1 IPSec connections IPSec Tunnel per Tunnel 1 Tunnel 2 or Non IPSec IPSec Connect...

Страница 106: ...vel Figure 6 6 Alarms Critical Major Critical Minor Warning Backhaul Traffic Shows the interfaces EPC HeMS and CA are connected CA Server Configuration CMPv2 Connection Status Status of the CMPv2 connection Valid values IN PROGRESS RE TRYING SUCCESS CMPv2Root Certificate Status Values supported VALID INVALID Operator Root Certificate Status Values supported VALID INVALID Operator Certificate Confi...

Страница 107: ...es on the Baseband Controller Controller Management interface Radio Point interface Table 6 4 CORE LED local network connectivity issues State Events Red solid Internet No Interface hardware issues Verify core network connectivity The core network includes IPsec connection Configuration from HeMS MME connection Table 6 5 CORE LED states State Events Green solid Power ON Connection to MME Yes Amber...

Страница 108: ...onfiguration from HeMS Chapter 6 Verifying the OneCell installation 6 10 913035 4 0 04 June 2019 DRAFT Verify OneCell RF coverage To verify the OneCell RF coverage Check connectivity on UEs Use UE Apps for checking Serving Cell PCI NOTE Examples of Apps for verifying RF coverage are NEMO ANITE UE Logs can be used for debugging RACH issues during UE connection ...