Power Tail Installation to RRU, Blue -48VDC and Black 0V
After the trunk cable is mounted measure
distance to determine the length of the
bird resistant sleeve and power conductor.
Remove bird resistant connector by loosening the gland
nut. Open the safety clip with a screwdriver. Pull the
connector off the bird resistant sleeve. Push the safety clip
back into the connector.
X
X
2
1
3
4
Cut bird resistant sleeve at . Be
careful not to cut the power
conductor inside of the bird proofing.
Dispose of excess bird proofing.
X
X
1
2
4
3
1
2
3
4
5
Replace bird resistant connector by sliding connector over
cable while twisting clockwise. Tighten the gland nut on the
power cable.
1
1
2
2
Route power to RRU, Connect and lock gland on the RRU entry plate before installing cover.
Entry plate will sit on the threaded portion of the gland nut.
+ -