Visit www.commscope.com for complete specifications on all the products listed
Bulletin # 7693902 Rev. L
Technical Publication
8
Device designed for cleaning the ferrule end faces of Fibre connectors
Open guide cap, insert connector into guide, push the outer shell to start cleaning the connector interface, a "click"
sound indicates end of a cleaning process, repeat, close cap immediately after use.
Caution:
Be careful not to slant connector while inserting into the Guide cap. Do not overly exert force during insertion
as this may cause damage to both the connector and the cleaner.
Section 5: All in one cleaner
Guide
Connector
Push Cleaner X2
Cap
There are 3 basic principles that are critical to achieving an efficient Fibre optic connection:
1. Perfect Core Alignment
2. Physical Contact
3. Pristine Connector Interface
Today’s connector design and production techniques have eliminated most of the challenges to achieving
core alignment and physical contact. What remains challenging is maintaining a pristine end-face. As a result,
CONTAMINATION is the #1 reason for troubleshooting optical networks.
Implementing the process of cleaning and inspecting before mating can reduce the time spent troubleshooting,
optimize signal performance and prevent damage.
Inspecting
Is It
Clean?
No
Connect
Yes
Inspect
Clean
Clean
Abrasive particles (i.e. rock dust) can
cause permanent damage to the
interface. If interface is scratched it cannot
be repaired, it would need to be replaced.
!
Scan to
view video
Part Number
Description
FCCT – MPO
MPO Connectors
FCCT – ODC
ODC compatible connector
FCCT – L
DLC
Connectors
Part Number:
FCCT - L (shown)