Visit www.commscope.com for complete specifications on all the products listed
Bulletin # 7693902 Rev. L
Technical Publication
12
Feed power conductor into power box. Prep
cable to dimensions listed on cover. Wire RRU
and close lid. Cable gland needs to be flush
with the bottom of the power box. Close door,
install locking screws.
Fibre
Power
RRU
+ -
+ GND -
8
For RRUs 3256 and 3929 remove 75 mm of length from the 11 mm conduit
then slide the conduit inside of power tail bird resistant sleeve. Replace
bird resistant connector by sliding connector over cable while twisting
clockwise. Tighten the gland nut on the power cable.
1
2
1
2
6b
7
Place tape at end of conduit
to build up thickness with for
proper clamp seal
6X
!
If jumper breakouts require staggering, install
additional provided piece of bird resistant sleeve
to cover both jumpers between the RRU and lower
grommet. Close door, install locking screws.
Additional bird resistant sleeve
(42 mm dia. 80 mm length)
RRU
+ -