Visit www.commscope.com for complete specifications on all the products listed
Bulletin # 7693902 Rev. L
Technical Publication
10
Section 7: Fibre Tail Installation DFJ-4S112B
+ -
+ -
+ -
+ -
1
2
3
Tighten the ODC compatible connectors to 1 N•m (8.8 in−lb).
Slide protective sleeve over the connectors and onto the protective sleeve .
Tighten both ends of the protective sleeve.
75 mm
(2.95 in)
+ -
Corrugated sleeve
Gland Nut
4
Place gland nut on edge of RRU. Connect the Fibre
to the RRU then tighten the RRU clamp on corrugated
sleeve over Fibre subunit.