5.2.2.
Standard indexing terminal 1:4 splitter with
reverse port
In this configuration, the terminal will drop the first fiber
from the incoming 12 fiber strand. This fiber will be
routed to an integrated 1:4 splitter. The outputs of this
splitter are DLX adapters or full size hardened adapters
(depending on the housing type). The others 11 fibers
from the incoming 12 fiber strand cable will proceed
unsplit and be terminated on a HMFOC adapter port,
together with the fiber coming from the reverse port.
The fiber coming from the reverse port will take # 12 of
the outgoing 12 fiber HMFOC, the incoming fiber # 2 will
take # 1 of this outgoing 12 fiber HMFOC.
The HMFOC adapter port is colored green and indicated
with an ‘A’ on the terminal. The reverse port is colored red
and indicated with a ‘R’ and the terminal.
Image below shows the schematics inside the terminal.
The 12 fiber strand cable terminated on a female HMFOC
of this terminal is connected to the green HMFOC
adapter port of its up-stream terminal (to the FDH in case
of the first terminal of the chain), a forward feed path is
created. 4 subscribers (homes) can be fed around this
indexed terminal by connecting a connectorized drop
cable (DLX or full size hardened) to one of the 4 black
dust cap adapter ports.
Up to 12 indexed terminals can be connected one after
the other (link installation).
Image below shows the available ports and color code of
the adapters of this terminal configuration:
DROP
DROP DROP DROP
HMFOC
DROP
Fiber 1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
HMFOC Adapter port
Drop port
Reverse port
5.1.3.
Specifications
PARAMETER
SPECIFICATION US
SPECIFICATION IEC
Environmental
GR-771-CORE,
and GR-3120-CORE
(HMFOC)
IEC 61753-1 Ed2
CAT A&G
Operation
Temperature
–40ºF (± 3.6º) to 150ºF
(± 3.6º)
–40ºC (± 2º) to 65ºC
(± 2º)
Installation
temperature
23°F to 113°F
- 5°C to 45°C
Humidity
0% to 100%RH
Water resistance NEMA 6
(10-foot water head for
7 days without leakage)
IEC 60529-IP 68 (till 3
meters for 7 days)
Flammability
UL94-5VA
Color
Black
Both housings are designed to meet aerial and pedestal
conditions. For hand-hole application, the housings are
designed to meet the conditions for hand-holes located
up to 3 meters (10 feet) under ground.
5.2.
Configurations
To build the network, each housing type is available in 4
configurations:
• Standard indexing terminal with 1:4 splitter
• Standard indexing terminal with 1:8 splitter
• Indexing only
• Branch terminal
5.2.1.
Color code (ports)
To ensure correct installation, the terminal ports are color-
coded:
BLACK
forward feed
DLX or full size hardened connector
single-fiber drop (split signal)
ORANGE
forward feed
DLX or full size hardened connector
single-fiber drop (unsplit signal)
RED
reverse feed
DLX or full size hardened connector
single-fiber drop or HMFOC
GREEN
HMFOC
12 fiber cable output to the next terminal
BLUE
HMFOC-branching only
12 fiber cable output that route a portion
of the 12 input fibers to another terminal