12.1. Connector components
The basic components of the drop cable connector are
shown in Figure below. The dust cap threads onto the
connector coupling nut. A pair of O-rings on the connector
body provide a tight seal when the dust cap is in place.
A pulling eye is provided in the end of the dust cap for
pulling the drop cable through conduit.
Do not exceed a pulling force of 444.8N (100 lbs) and
when connected, don’t exceed cable pull of 111.2 N
(25 lbs).
DUST CAP
O-RINGS
COUPLING NUT
CONNECTOR
BODY
12. Full size hardened connector
installation
Indexing terminals with the full size hardened connector
housing use full size hardened connector technology to
connect a subscriber to the drop adapter ports (black dust
cap) and to connect the reverse feed (red dust cap).
CommScope full size hardened connectors and
adapters provide sealed environmental protection for
the subscriber drop cable connector and the SC adapter
mounted within the full size hardened connector housing
optical adapter port. The following sections provide a
description of the connector and adapter components
and provide instructions for connecting or disconnecting
the drop cable to/from the optical ports. Also a section
describing the cleaning procedures for both connector
and adapter is integrated.
12.2. Adapter components
The basic components of the optical port hardened
adapter (black and red dust cap) on the full size hardened
connector housing are shown in the Figure to the right.
The dust cap threads into the adapter housing. An O-ring
on the dust cap provides a tight seal when the dust cap is
in place. The 216B key tool is required to remove the dust
cap.
12.3. Full size hardened connector
specifications
Designed to GR-3120 / IEC 61753-1 Ed2 Category G
generic performance requirements for hardened fiber
connector.
GR-20 / IEC 60794-3-10 generic requirements for single
mode fiber optic cables.
Latching
: Twist-lock secure long term connection.
Physical Contact
: Angled Polished Contact (APC),
standard 8-degree angle
Retention Force
: 444.8 N (100 lbs)
Cable pull when connected
: 111.2N (25 lbs)