![CommPower CP-145 Скачать руководство пользователя страница 98](http://html1.mh-extra.com/html/commpower/cp-145/cp-145_installation-and-administration-manual_2643550098.webp)
Appendix B. Error Messages
/cpe/cp-145/adm/004 (07/14)
B-7
has failed. See the event log for details. The failed FEP log.ss file
contains details.
312:
RCF error, trying to access file. RCF error has occurred trying to access
file. A UNIX file I/O call has failed for one or more RCF files when
attempting to send RCF files to a processor. This error is very serious
because the processor(s) that reported the failed condition will now
remain in a state in which it will not be able to be fully operational. For
example if the error occurred during startup the processor will never
achieve ACP-145 operational status. If the error occurred during a
distribute condition the system will remain in the distribute state. Any
subsequent install RCF command will be rejected. Toggling the FEP
OFFLINE followed by ONLINE should remedy the error. The failed
FEP log.ss file contains details.
313:
AM failed to return a valid msg. AM has failed to return a valid msg.
The SSR wait for receipt of a ACP-145 application process to return a
good response has failed. Serious system problems may be responsible.
Install RCF command will be rejected. Toggling the FEP OFFLINE
followed by ONLINE may remedy the error. Examine the AM log file
for details. The failed FEP log.ss file contains details.
314:
Invalid event for current state. The finite state machine has rejected a
specific operator SCP command or an illegal operation has been
detected by the state machine. Check log.ss for specific event no.
315:
Cannot start processor, invalid log processor number. Cannot start
processor due to invalid log processor number. The operator has
attempted a "START PROC" command to a processor that has an
invalid logical processor number. The log processor # may be (-1) in
the case of the backup processor, or (-2) if it is a FEP in a standby
condition. You are only allowed to start a processor with a logical
processor number of 1 - 5.
316:
Processor unavailable/is in use.
317:
Operator command rejected. Operator command rejected at this time.
ssr_ctl has determined that the operator has requested an operation
which cannot be performed because it is either currently in progress or
that performing such a request would jeopardize current system
operation.
400:
RP cannot locate msg in database
401:
RP cannot retrieve msg – security exceeded
402:
RP cannot build msg into proper structures
404:
Sync in progress, can't process. This control message cannot be
processed at this time due to the "in-progress" state of the
core/shadow file synchronization. Once the files have been
synchronized (or synchronization has been turned off), the message
can be processed.
Содержание CP-145
Страница 30: ...ACP 145 Installation and Administration Manual 3 8 cpe cp 145 adm 004 07 14...
Страница 41: ...Chapter 3 Basic MTA ACP 145 Configuration cpe cp 145 adm 004 07 14 3 19 C O M M P O W E R...
Страница 83: ...ACP 145 Gateway Installation and Administration Manual 5 40 cpe cp 145 adm 004 07 14 C O M M P O W E R...