Chapter 3. Basic MTA/ACP-145 Configuration
/cpe/cp-145/adm/004 (07/14)
3-15
.p12 certificate file for this gateway. Select the file and click
Open
to
save that file and path to the Certificate file field. Enter the password for
the .p12 file, and then check the
Save
button.
51.
Select the
Security Tables
tab to configure the SPST and SPTT files
used for message translation. Click the first
ellipsis
button to browse to
the local location of the SPST file. Click on the second ellipsis button to
browse to the local location of the SPTT file. Click on the third ellipsis
button if a second SPTT file is to be used.
52.
Select the
OK
button to return to the CP-145(F) Configuration main
screen.
3.2.1.2.14
X400
53.
Select the
X400
button in the CP-145(F) Configuration Utility main
window. The Edit X400 Gateway Assignments window is displayed.
54.
Enter values in the MTS Local ID field and in the MTA Name field that
is
NOT
the same as the collocated MTA name.
55.
Enter the Global Domain values by entering the Country, ADMD, and
PRMD fields.
56.
Select the
OK
button to return to the CP-145(F) Configuration main
screen.
3.2.1.3
Define Security Parameters
1.
Select the
Security
tab in the CP-145 Gateway Configuration Utility
main window. Security parameters are displayed.
2.
Select the required security level from the drop-down menu in the
Highest Security field.
3.
Select
Install
from the File Menu in the CP-145 Gateway Configuration
Utility main window. The changes are installed.
3.2.1.4
Define Channel Configuration Parameters
The CP-145(L) requires a minimum of 2 channels (and a maximum of 10),
one for ACP-128 communications and one for XML communications. The
CP-145(F) requires that two channels be configured, one for X.400
communications and one for XML communications. For each channel,
perform the following steps:
1.
Select the
Channel
tab in the CP-145 Gateway Configuration Utility
main window. Channel parameters are displayed.
2.
Use the arrow icons in the Channel Number field to select the number of
the channel to be used for your I/O communications.
3.
Select the required security level from the drop-down menu in the
Security Type field.