![CommPower CP-145 Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/commpower/cp-145/cp-145_installation-and-administration-manual_2643550039.webp)
Chapter 3. Basic MTA/ACP-145 Configuration
/cpe/cp-145/adm/004 (07/14)
3-17
3.2.2.1
CP-145 Gateway Startup
1.
Log onto the system as an account with local administrator privileges
2.
Select
Start>>ACP-145 Local Gateway (or ACP-145 Foreign
Gateway)>>Start CP-145
. The ACP-145 Start Monitor will be displayed
and monitor the start-up process.
3.
When selectable, select the
User Interface
button on the ACP-145 Start
Monitor. The ACP-145 User Interface is displayed.
3.2.2.2
Configuring The CP-145 Gateway
Once the ACP-145 and the ACP-145 user interface have been successfully
started, online configuration can occur. Online configuration consists of a
series of steps that need to be performed only once at initial startup. To
configure the ACP-145 Gateway, perform the following steps:
3.2.2.2.1
Channel Initialization
Each of the channels configured in “Define Channel Configuration
Parameters” above must be set-up (or initialized). To do this, perform the
following steps:
1.
From the ACP-145 Gateway User Interface, select the
Channels
button
in the Tool Bar. The Channel Operations dialog is displayed.
2.
In the Channel Number field, enter one of the channel numbers
configured in “Define Channel Configuration Parameters” above.
3.
Once the channel number has been entered, select the
Setup
button in
the Channel Operations dialog. The Channel Setup dialog is displayed.
4.
Select the desired channel type via the respective tab in the Channel
Setup dialog. For the X.400 channel (CP-145(F)), use the Email channel
type; for the XML channel, use the XML channel type, for a Mode I
Legacy channel (CP-145(L)), use the Mode I AID type. Once a channel
type has been determined, configure the associated data vales in
accordance with the procedures given in “Set up Channel Parameters” in
Chapter 3 of the
ACP-145 Gateway User’s Guide
.
5.
Once the desired options have been selected/entered, select the
OK
button in the Channel Setup dialog. A Response dialog is displayed
indicating the current parameters for the channel.
6.
Select the
Close
button in the Response dialog. The Response dialog is
closed, and the Channel Operations dialog is displayed.
7.
Verify that the desired channel number still appears in the Channel
Number field and select the
Open Channel
button in the Channel
Operations dialog. A Response dialog is displayed indicating the current
parameters for the channel. The Channel Status parameter should
indicate Open.
Содержание CP-145
Страница 30: ...ACP 145 Installation and Administration Manual 3 8 cpe cp 145 adm 004 07 14...
Страница 41: ...Chapter 3 Basic MTA ACP 145 Configuration cpe cp 145 adm 004 07 14 3 19 C O M M P O W E R...
Страница 83: ...ACP 145 Gateway Installation and Administration Manual 5 40 cpe cp 145 adm 004 07 14 C O M M P O W E R...