Radiator System Description  

The Steak Age models use side anti-dew tube and Independent cooling system. 

 

 

Turn On Your Steak Ager 

1.

 

The allowable voltage and frequency are marked on the rating label, the socket must be properly grounded 
and protected by a fuse 

2.

 

The socket must not be directly behind the steak ager and must be easily accessible 

3.

 

Do not use extension cables or extension sockets to connect steak ager 

4.

 

Do not use stand-alone inverters or energy-saving plugs, otherwise the electronic control system will be at 
risk of damage 

5.

 

Do not look directly at the light line from close range, it will hurt your eyes 

6.

 

Plug in and switch on the cellar by pressing on the power button for a few seconds
When you use the Steak Ager for the first time (or restart the Steak Ager  after having it shut off for a long 
time),  there  will  be  a  few  degrees  variance  between  the  temperature  you  have  selected  and  the  one 
indicated on the LED readout.  This is normal and it is due to the length of the activation time. Once the 
Steak Ager  is running for a few hours everything will stabilize. 

 
Important: If the unit is unplugged, power is lost, or turned off, wait 3 to 5 minutes before restarting the unit. 
The Steak Ager will not start if you attempt to restart before this time delay. 
 

Security Lock 

The  mature  machine  has  a  lock  device  installed  (not  all  products  have,  please 
configure  according  to  the  actual  product).  As  shown  in  the  figure,  rotate  90°, 
unlock in the direction of Figure 2, reverse 90° from 2, and lock the safety lock in 
the direction of Figure 1. 
 

 

Содержание 7525 Series

Страница 1: ...Dry Age Cabinets 7525 Series User Manual Gebruikershandleiding Gebrauchsanweisung Le mode d emploi ...

Страница 2: ...ak Age 7 Open angle size drawings 9 Radiator System Description 10 Turn On Your Steak Ager 10 Security Lock 10 Operating Noises 11 Start Tips 11 Temperature Setting 11 Temperature Display Board Operating Instruction 12 Defrost System 14 Removing Shelf 14 Humidification System Description 14 Instructions For Adding Water and Replacing Absorbent Cotton 15 Reversibility Of The Door 19 Door timeout al...

Страница 3: ...red goods or spoilage Furthermore the appliance is not suitable for use in hazardous areas Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance Notices in Operating 1 Children 3 8 years old are not allowed to take or place things from the Steak Ager 2 Opening the door for a long time may cause the temperature of the Steak Ager to rise significantly 3...

Страница 4: ...bustion supporting sprays 14 If the power cord is damaged in order to avoid danger non original professional authorized personnel or personnel with professional licenses may not repair and replace the product please contact the supplier immediately Danger 1 Pay attention to the danger that children may be trapped in the box 2 Do not let children operate the product alone 3 Do not use electrical eq...

Страница 5: ...ng instructions When installing the product must connect the grounding wire Please use the grounding power socket correctly to prevent the leakage of the wire and reduce the risk of electric shock The Steak Ager is equipped with a grounded power cord Improper installation of grounding may cause electric shock If you have any questions about the grounding installation information please consult a p...

Страница 6: ...st 5 days after slaughter 4 We recommend the best cooked beef use young beef with fat and marbled 5 Hang the whole piece of meat on the rack or put the cut pieces on the shelf Installation Guide 1 Built in Steak Ager are front venting but are not designed to be fully integrated behind a joinery door 2 Please follow the installation diagram when installing built in Steak Ager No less than the minim...

Страница 7: ...SA VI120SA VI180SA can be free standing installation or built in installation For specific installation dimensions please refer to the following embedded installation diagram Note The appliance must be positioned so that the plug is accessible after installed 7525 0100 7525 0105 ...

Страница 8: ...8 www combisteel com 7525 0110 ...

Страница 9: ...9 www combisteel com Open angle size drawings 7525 0100 7525 0105 7525 0110 ...

Страница 10: ... pressing on the power button for a few seconds When you use the Steak Ager for the first time or restart the Steak Ager after having it shut off for a long time there will be a few degrees variance between the temperature you have selected and the one indicated on the LED readout This is normal and it is due to the length of the activation time Once the Steak Ager is running for a few hours every...

Страница 11: ...eat can be used but for a maximum of 14 days please remove foil 5 Our recommendation for the best dry aged beef use meat from a young cow with an ordinary fat cover plus good marbling 6 Hang the complete back on the hangers of your Steak Ager or put the individual cuts on the shelves 7 Load capacity max 2x half strip loins on the bone with a length of 0 5m therefore you will need 2 hangers 8 Load ...

Страница 12: ...e on 1 hour 2 Manual control The steak ager is power on Please press this button 3 seconds the UV light will be always on Please press light button 3 seconds again and then the UV light will turn off 3 When the UV light turn on the UV light will be closed when door is open and it will be on when door is closed Note The life of the UV lamp is 12 months Exceeding the service life will greatly reduce...

Страница 13: ... is power on If the UV light doesn t be turned on by human the UV light will turn on for every 24 hours The times will be 1 hour It means every 24 hours the UV light will be on 1 hour 2 Manual control The steak ager is power on Please press light button 3 seconds the UV light will be always on Please press light button 3 seconds again and then the UV light will turn off 3 When the UV light turn on...

Страница 14: ...e Steak Ager is not totally sealed fresh air admission is permitted through the drainpipe Notes During the refrigerating cycle heat is given off and disperses through the external surfaces of the Steak Ager Avoid touching the surfaces during those cycles Removing Shelf Shelf taking According to below instruction drawing to press one side of shelf limit pin extract and remove the shelf from the oth...

Страница 15: ...illing reminder function When the water tank is short of water there will be a buzzer prompt At the same time the display window will display E5 to prompt a water shortage fault When this fault occurs the lighting lamp will flash At this time it is necessary to add water manually The display panel E5 disappears automatically within 10 seconds after the water addition operation is completed and the...

Страница 16: ...ater and replacing absorbent cotton 7525 0100 add water manually The steps are divided into 1 2 3 4 steps 1 Uncover the water tank cover A according to the arrow 2 After opening the water tank cover you can see the water tank take out the water tank according to the arrow direction ...

Страница 17: ...e water tank After opening you can add water After adding water put it back into the product cover the water tank cover and complete the water adding operation 4 Replace the absorbent cotton Take out the water tank assembly and update the absorbent cotton according to the view ...

Страница 18: ... the machine must be turned off before operation 1 Place a 2L water box under the drain then unscrew the drain cover to drain according to the following view 2 2 Drain cover operation diagram Remove the display board and the water tank baffle according to the view operation and unplug the connecting wires and take overs connected to the fan water inlet pipe etc on the water tank ...

Страница 19: ...may need to rotate the door 180 degrees or symmetrically change the direction of the door according to the product s own configuration 2 The door may be irreversible depending on the type of handles of the steak ager or the door may need to be opened and replaced when ordering Warning To avoid accidents during the process of changing the door we recommend that you get assistance The glass door is ...

Страница 20: ...door shaft core 6 from the two ends of the top of the door Take out the door and set aside Drawing 2 5 Discharge the upper and lower door hinge 7 8 by M5 inner six angle screwdriver Tool 5 then to assemble the door hinge on the opposite side Drawing 3 and 4 6 Reverse the door 180 degrees then Install the door on the opposite side of the cabinet Drawing 5 7 Finally install the decorative nail and d...

Страница 21: ...se use the electric drill to drill the holes of the door a bit big in surface side in order to install the handle perfectly Meat Quality Recommendation The best meat recognized for Dry aging is rib eye on the bone It is always best to purchase from a dealer who sources their meat from a good quality abattoir The younger the animal the better the result It is always recommended to buy a piece of me...

Страница 22: ...ho should carry out an inspection of the circuit sealing system Similarly any intervention on the electrical circuit should be performed by a qualified electrician Note Any intervention performed by a non authorized technician We will lead to the warranty being considered as null and void Power Failures In the event of a power interruption all previous temperature settings are automatically preser...

Страница 23: ...r is not closed completely The temperature is not set correctly The door gasket does not seal properly The light does not work Not plugged in The circuit breaker tripped or a blown fuse The light is damaged The light is OFF Vibrations Please check whether the steak ager is on level ground The Steak Ager seems to make too much noise The rattling noise may come from the flow of the refrigerant which...